31
EN
Connections
1
Connection sockets for service
devices
2
Rotary switch for adjusting the
output assignment
3
Hi-O Technology
TM
connection
4
2 Potential-free outputs
5
DIP switches 1 and 2
6
SYSCON7 for open collector
outputs
7
Hi-O Technology
TM
SYSCON4
connection
8
Jumper 1 and 2
9
Four digital inputs and connec-
tion for a fire alarm system
Important!
Risk of destruction if inputs are controlled non-isolated:
the digital inputs (Fig. 2
page 30 –
9
) may only be controlled by potential-free contacts (release button,
relay contact).
Status messages/LEDs
The LEDs (Fig. 2 –
A
and
C
) show the status of the
OneSystem IO module uP
.
LED green
LED red
Meaning
illuminated
off
the IO module is in operation
Flashes
Flashes
the IO module is offline
A
Summary of Contents for N5951000PILL000
Page 25: ...25 DE ...