B
A
Slide "B" into "A"
866-474-9766 Technical Department
www.rixson.com
Model 1351
Max. Gate Size: 54" x 120"
Pull Side Mount ONLY
1
Locate and mark closer mounting plate.
Using one aluminum slide track (B), insert it
into the closer mounting plate (A). This insures
the track will be in exact alignment to the closer
body. Mark the hole locations on the post.
IMPORTANT: Position (A) so the closer portion of
the plate will be mounted to the pull side of the gate.
Mount plate to post on pull
2
side of gate.
(Note that this
plate is not handed so it can be
mounted in either orientation.) Use
and holes for masonry post
mounting. Use and
holes for
tubular post mounting. Attach (A) with
four hex screws. If the gate post is
masonry, use the longer screws with
the anchors included in the package. If
tube post extends above gate, use
masonry hole locations.
25mm
5.5mm
50mm
40mm
6mm
8mm
8mm
Tube Post
Masonry
Post
OS19510 (06-13)
1351 Gate Closer
ASSA ABLOY
RI X SON
®
Hinge
Side
Masonr
y
Anchor
Push
Side
Closer P
osition
Tools Required
OS19510 (06-13)