5
1-800-727-5477 • www.sargentlock.com
7800 and 8200 Series Mortise Lock
Installation Instructions
Used with VN1 Escutcheon Trim and V Series Indicators
Copyright © 2019, 2020, 2021, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or
in part without the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending
and/or patent www.assaabloydss.com/patents.
A8260D 11/21
Installation, continued
5
e
Install Cylinder
f
Install Outside Front
1. Thread cylinder into lock until flush with escutcheon surface. (Figure 9)
• Pull key slightly out of cylinder to help thread into lock body.
2. Tighten cylinder clamp screw with #1 Phillips screwdriver.
• Check operation and adjust cylinder if necessary.
Notes:
•
SARGENT logo must be horizontal and on top. (Figure 10)
•
If double cylinder function is used, repeat steps 1 and 2 for second cylinder.
•
Removable Core or Interchangeable Core cylinders require a control key (key
stamped with C) to remove and install the core. This is not provided standard;
it must be requested separately. If requesting 1-bitted control key, specify
113511 cut.
Cylinder
Cylinder
Clamp
Screw
Figure 9
Incorrect
Key and cylinder must be rotated as shown.
Correct
Figure 10
1. Tighten the two (2) lock screws completely. (Figure 11)
2. Attach outside front with two (2) flat head screws #8-32 x 1/4".
g
Perform Functional Check
DO NOT FORCE if resistance is encountered during functional check.
Refer back to Rehanding Indicator (if required) section to ensure
correct handing. Rehand if necessary.
1. Insert key into cylinder (if present) and rotate:
• Ensure there is no friction against lock case or any other obstructions.
2. Check key retracts latch:
• Key should rotate freely.
3. Throw deadbolt (if present):
• Check key retracts both deadbolt and latch.
4. Test
levers:
• Confirm latch and deadbolt (if installed) retract.
5. Verify indicator displays correct status when locked and unlocked.
Figure 11
Lock
screw
Outside
front
Lock screw
#8-32 x
1/4" screws