To comply with UL certifications and for security:
Fasten exit chassis to door using (4) #10 wood
screws (for wood door) or (4) #10-24 machine
screws (for metal door).
6 Secure Exit Chassis
(4) #10 Wood Screws or
#10-24 Machine Screws
Inside of Door
(2) #12-24 x 1-7/8”
Flat Head Screws
(Through-bolts
Cylinder to Chassis)
Fig. 6
For devices without cylinder, go to Step 6.
1. While installing the rim cylinder, support the tail piece of the cylinder,
verifying its engagement with the top hub of the exit chassis.
Note: Be sure ET harness is clear of cylinder and tailpiece.
2. Secure the cylinder by through-bolting the cylinder
through the exit chassis using (2) #12-24 x 1-7/8”
connecting screws (see Fig. 6).
3. Verify that the key retracts latchbolt.
Position cylinder so that the SARGENT logo
is right-side up.
Correct Incorrect
Fig. 5B
5 Install Cylinder
Fig. 5A