1-800-810-WIRE • www.sargentlock.com • A8185D
Copyright © 2016, 2019, 2021, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
04/30/21
IN120 / IN220 Exit Device
26
Inside of Door
Fig. 2A
Fig. 2B
1. Next feed cables/connectors through the inside mounting assembly (and gasket if required*).
2.
Insert and partially tighten (2) through-bolts prior to installation of connectors.
NOTE: Cable lengths exaggerated for illustrative purposes
2 Outside Reader and Mounting Plate Assembly Installation (Continued)
3. Secure ground lug(s) with #6-32 machine screw (Fig. 2B).
*Gasket is required for outdoor installations.
If installing with gasket; separate gasket from mounting plate to feed cables/connectors
through holes as indicated (Fig. 2A).
Once cables/connectors are fed through, reattach gasket to mounting plate.
Gasket*
Inside
Mounting Plate
DPS
Lock Body
Harness
Reader Harness
Through - bolt
Through - bolt
Cat5e or higher cable
from hinge
(with ground wire)
For IN220 installation only
Ground wire for
IN220 (PoE)