04/30/21
Copyright © 2016, 2019, 2021, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN120 / IN220 Exit Device
1-800-810-WIRE • www.sargentlock.com • A8185D
27
3 Installation of Connectors
Important Note: Before you secure the connectors
*Supplied tube contains 5 grams of silicone dielectric compound (grease)
**Evenly distribute grease; full application requires approximately 2.5 grams
CAUTION - Do not allow debris to enter connector contacts
Ensure connectors are covered with silicone dielectric compound
(grease)*
IMPORTANT: Do not run wires through bottom hole in plate (Fig. 3A, B) - it will
damage wires and the controller connector. Route wires around flange, do not
route wires through the flange hole (Fig. 3B).
• Snip end of packet to dispense grease
• Ensure all connector pins and contacts (Fig. 3A) are
covered -
do not overfill or over-apply**
Secure Mounting Plate
• Tuck excess cable into wire hole on inside of door
• Secure the mounting assembly while ensuring proper
alignment of outside reader and fully tighten the (2)
through-bolts on the inside of the door to secure the
reader and plate to the door
Fig. 3A
SILICONE DIELECTRIC
COMPOUND
NO WIRES
THRU THIS
OPENING
FILL
FILL
APPLY
FILL
FILL
Secure the following connectors (Fig. 3A, B):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
Reader
(24-pin)
Board-to-Board
Connector
Fig. 3B
A
B
C
Fig. 3C
FILL
D
FILL
C. Secure the 24-pin card reader connector (Fig. 3B)
D. Ensure all openings on back of secured connectors are
covered completely with grease (Fig. 3C).