background image

04/30/21

Copyright © 2016, 2019, 2021, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved. 

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

IN120 / IN220 Exit Device  

1-800-810-WIRE • www.sargentlock.com • A8185D 

7

Parts Breakdown (Continued)

6

ITEM

PART No. 

DESCRIPTION

REQ’D

1

--

Cylinder Assembly (Reference Catalog for Available Cylinders)

1

2

--

Lever (Reference Catalog for Available Styles)

1

3

97-4105

Exit Trim (ET) With Cylinder

1

97-4106

Exit Trim (ET) Without Cylinder

52-4845

Motor Assembly (Separate - not shown)

1

4

68-7255

Chassis Assembly

1

68-7256

Chassis Assembly (Fire Rated)

68-5836

Chassis Assembly (Latch Guarding)

68-5837

Chassis Assembly (Fire Rated Latch Guarding)

5

01-4451

1/4-20 x 2-3/8” ET Screws

2

6

01-2273 

#10 x 1-1/4” Chassis Screws 

4

01-1185 

#10-24 x 3/4” Chassis Screws

4

7

97-0052 

#8-32 x 5/16” Cover Screws

4

8

68-0406 

Chassis Cover

1

68-1014 

Chassis Cover (With Guarding)

8877/8878 x ET x Lever Design  IN220 Rim Exit Device

4

1

2

3

7

8

5

6

Summary of Contents for SARGENT IN120 Wi-Fi Series

Page 1: ... ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Exit Device Installation Instructions IN Series IN120 Wi Fi IN220 PoE Exit Device Installation Instructions ...

Page 2: ... Manufacturing Company is prohibited 04 30 21 IN120 IN220 Exit Device 2 1 2 3 4 5 6 8 7 10 Table of Contents Warning 3 Regulatory Power Specifications 4 General Description 5 Hardware Specifications 5 Technical Specifications 5 Parts Breakdown 6 IN220 PoE Installation Wiring 9 Installation for 8877 8878 Rim Exit 13 Installation for 8977 8978 Mortise Type 19 IN120 IN220 Installation Instructions 25...

Page 3: ...ection 15 de la réglementation de la FCC L opération est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interférence nocive et 2 ce dispositif doit accepter n importe quelle interférence reçue y compris l interférence qui peut causer l opération peu désirée This equipment complies with FCC and IC radiation exposure limits set forth for general population uncontrolled en...

Page 4: ...es must be replaced with alkaline batteries only Optional Hard Power UL 294 Listed Power Supply Required 9 24VDC 300mA UL 294 Access Control Ratings Destructive Attack Level 1 Line Security Level 1 Endurance Level 4 Standby Power Level 1 UL Listed UL 294 Indoor Use CUL Listed ULC 60839 11 1 Grade 1 Compliance with IEEE 802 3 at or af specifications was not verified as part of UL 294 B IN120 Wi Fi ...

Page 5: ...i and IN220 PoE series locks offer HID multiCLASS SE technology in a streamlined design setting a new standard for aesthetics and performance providng heightened identity security and multiple credentials including mobile access The IN120 exit device uses IEEE 802 11 Wi Fi communication and a flexible feature set for easier more cost effective installations allowing facilities to leverage their IT...

Page 6: ...ited 04 30 21 IN120 IN220 Exit Device 6 Parts Breakdown 6 Tools Required 2 Phillips screwdriver Flat head screwdriver Security allen wrench ITEM No DESCRIPTION 1 Outside Escutcheon Assembly 2 Inside Mounting Plate Assembly includes Gasket 3a PoE Controller Assembly 3b Wi Fi Controller Assembly batteries included 4 Inside Escutcheon Assembly with Privacy Button 5 AA alkaline batteries 6 1 4 5 3a 3b...

Page 7: ...nders 1 2 Lever Reference Catalog for Available Styles 1 3 97 4105 Exit Trim ET With Cylinder 1 97 4106 Exit Trim ET Without Cylinder 52 4845 Motor Assembly Separate not shown 1 4 68 7255 Chassis Assembly 1 68 7256 Chassis Assembly Fire Rated 68 5836 Chassis Assembly Latch Guarding 68 5837 Chassis Assembly Fire Rated Latch Guarding 5 01 4451 1 4 20 x 2 3 8 ET Screws 2 6 01 2273 10 x 1 1 4 Chassis ...

Page 8: ...inder Assembly Reference Catalog for Available Cylinders 1 2 Lever Reference Catalog for Available Styles 1 3 97 4107 Exit Trim ET With Cylinder 1 97 4108 Exit Trim ET Without Cylinder 52 4845 Motor Assembly Separate not shown 4 99 2401 8900 Lock Body Assembly LHR 1 99 2402 8900 Lock Body Assembly RHR 99 2403 8900 Lock Body Assembly LHR Non Beveled Door 99 2404 8900 Lock Body Assembly RHR Non Beve...

Page 9: ... EAC Software System A PoE frame harness assembly B PoE data hinge from McKinney C PoE door harness from McKinney D IN220 PoE Lock E For locks with external DPS Door Position Switch Door width determines length Network Cable Network Switch 802 3af Surface Mount RJ45 B C E D A B B C D E Wiring methods shall be in accordance with the National Electrical Code ANSI NFPA70 CSA 22 1 Canadian Electrical ...

Page 10: ...th Ground in 15 Frame Harness Cable drain wire concealed in shrink tubing Patch Panel Drain Wire Terminated on Rack Cable Cat5e or higher 24 AWG RJ45 F Jack Approved Software Certified Integrator CI supplies and terminates the B Splice connector and the male RJ45 connector from harness to end user provided facility cable Supplied by End User PoE Switch PoE Switch is Terminated to Earth Ground Patc...

Page 11: ... for Earth Ground in 15 Frame Harness Cable drain wire concealed in shrink tubing Frame Harness Installation Hinge side of PoE Frame harness 4 pin M 6 pin M Frame PoE Hinge PoE Data Hinge Hinge side harness connectors 4 pin female molex connector 6 pin female molex connector with ground wire Lock side harness connectors 4 pin female molex connector 6 pin female molex connector with ground wire B A...

Page 12: ...rs go on only one way They cannot be plugged to incorrect position Do not force and do not offset connectors Be sure they are completely seated flush PoE Door Harness IN220 PoE Lock 4 pin F 4 pin M 4 pin F 6 pin F 6 pin F 6 pin M Cable Cat5e or higher 26 AWG stranded shielded 100ohm Drain Wire PoE Lock D C RJ45 M 7 IN220 PoE Installation Wiring Continued Inside of Door PoE Harness Cat5e or higher ...

Page 13: ...ield Template A8149 ships with product Door Manufacturer s Template 4712 Inside of Door Outside of Door Check hand of door The exit device is non handed and the trim is field reversible Door should be fitted and hung Left Hand Reverse LHR Outside Inside Right Hand Reverse RHR Fig 1A A Verify Hand and Bevel of Door B Verify Product Label 8 Installation Instructions for 8877 8878 Rim Exit Through Bo...

Page 14: ...tal doors have 3 4 raceway to the controller cutout Refer to template A8214 1 Insert connector end of DPS through the raceway on the latch edge of the door Fig 2A Note For metal doors use DPS Collar 2 Push DPS firmly into place by hand IMPORTANT DO NOT TAP SWITCH WITH ANY TOOL Wood Frame Metal Frame Dim 1 3 8 3 4 Horizontal of Strike Door Position Switch Hole Vertical of Strike Dim 2 From template...

Page 15: ...nnector and two different sized ground lugs Fig 3A 1 Feed 6 pin connector and larger ground lug straight through to outside of door Fig 3A B while feeding smaller ground lug into wire hole up through wire channel and out through inside of door Fig 3C DO NOT PINCH THE WIRE HARNESS 2 Begin to secure the exit chassis with through bolts to the ET trim using 2 1 4 20 x 2 3 8 flat head machine screws 3 ...

Page 16: ...Route ET wire harness connector through the cylinder hole up and through the wire run channel to the controller cutout For metal doors Route ET wire harness through the cylinder hole out the controller cutout C Pass top ET trim mounting post through chassis harness ground lug D Ensure ET spindle engages the lower hub of the exit chassis E Fully tighten 2 chassis through bolts Fig 4B 4 Mount Exit T...

Page 17: ...e Exit Chassis 4 10 Wood Screws or 10 24 Machine Screws Inside of Door 2 12 24 x 1 7 8 Flat Head Screws Through bolts Cylinder to Chassis Fig 6 For devices without cylinder go to Step 6 1 While installing the rim cylinder support the tail piece of the cylinder verifying its engagement with the top hub of the exit chassis Note Be sure ET harness is clear of cylinder and tailpiece 2 Secure the cylin...

Page 18: ...art without express written permission of Sargent Manufacturing Company is prohibited 04 30 21 IN120 IN220 Exit Device 18 Secure chassis cover to chassis using 4 8 32 x 5 16 oval head machine screws Fig 7 7 Install Chassis Cover Fig 7 NOTE Cable lengths exaggerated for illustrative purposes To complete installation continue to Section 10 IN120 IN220 Installation Instructions ...

Page 19: ...installing hardware 2 Doors should be pre prepped recommended 3 Use appropriate templates IN220 template A8215 Field Prep Template Exit installation instructions A6705 Note Instruction examples show wood door installation For metal doors route cables inside door Left Hand Reverse LHR Outside Inside Right Hand Reverse RHR Fig 1A A Verify Hand and Bevel of Door 1 Door Preparation B Verify Product La...

Page 20: ...ceway to controller cutout and metal doors have 3 4 raceway to the controller cutout Refer to template A8215 1 Insert connector end of DPS through the raceway on the latch edge of the door Fig 2A Note For metal doors use DPS Collar 2 Push DPS firmly into place by hand IMPORTANT DO NOT TAP SWITCH WITH ANY TOOL Wood Frame Metal Frame Dim 1 3 8 3 4 Horizontal of Strike Vertical of Strike Dim 2 From t...

Page 21: ...xit Chassis Fig 3A 1 Slide mortise lock into door and loosely secure with 2 flat head screws NOTE Exit chassis harness consists of a 6 pin female connector and two different sized ground lugs Fig 3A 2 Feed 6 pin connector and larger ground lug straight through to outside of door Fig 3A B while feeding smaller ground lug into wire hole up through wire channel and out through inside of door Fig 3A D...

Page 22: ... through the cylinder hole up and through the wire run channel to the controller cutout For metal doors Route ET wire harness through the cylinder hole out the controller cutout C Pass top ET trim mounting post through chassis harness ground lug D Ensure ET spindle engages the lower hub of the exit chassis E Fully tighten 2 chassis through bolts Fig 4B NOTE Cable lengths exaggerated for illustrati...

Page 23: ...he exit chassis Note Be sure ET harness is clear of cylinder and tailpiece 2 Secure the cylinder by through bolting the cylinder through the exit chassis using 2 12 24 x 1 7 8 connecting screws see Fig 6 3 Verify that the key retracts latchbolt Position cylinder so that the SARGENT logo is right side up Correct Incorrect Fig 5A 5 Install Cylinder To comply with UL certifications and for security F...

Page 24: ...art without express written permission of Sargent Manufacturing Company is prohibited 04 30 21 IN120 IN220 Exit Device 24 Secure chassis cover to chassis using 4 8 32 x 5 16 oval head machine screws Fig 7 7 Install Chassis Cover Fig 7 NOTE Cable lengths exaggerated for illustrative purposes To complete installation continue to Section 10 IN120 IN220 Installation Instructions ...

Page 25: ... Exit Device 1 800 810 WIRE www sargentlock com A8185D 25 1 Outside Reader and Mounting Plate Assembly Installation 1 Orient reader keypad so LED lens is at the top 2 Feed the cable connector through door from outside to inside 3 Install reader to the outside of door by aligning mounting posts with the door preparation holes Hold reader flush against door while ensuring proper alignment LED IN120 ...

Page 26: ...h bolts prior to installation of connectors NOTE Cable lengths exaggerated for illustrative purposes 2 Outside Reader and Mounting Plate Assembly Installation Continued 3 Secure ground lug s with 6 32 machine screw Fig 2B Gasket is required for outdoor installations If installing with gasket separate gasket from mounting plate to feed cables connectors through holes as indicated Fig 2A Once cables...

Page 27: ...ge wires and the controller connector Route wires around flange do not route wires through the flange hole Fig 3B Snip end of packet to dispense grease Ensure all connector pins and contacts Fig 3A are covered do not overfill or over apply Secure Mounting Plate Tuck excess cable into wire hole on inside of door Secure the mounting assembly while ensuring proper alignment of outside reader and full...

Page 28: ...rease to connector located on back of Controller FIG 4B C Back of Controller Be sure to apply grease to connector and recessed area surrounding connector 3 Installation of Connectors Continued Fig 3D Front of Controller PoE shown Important Note If you are installing IN220 PoE For more detail refer to section 7 Installation Wiring A Frame Harness Installation Crimp wires to RJ45 M Connector PoE onl...

Page 29: ...e connector to female RJ45 port on controller board Fig 5A 2 If power is enabled LED will flash and lock motor will cycle A IN220 PoE 1 Insert bottom tab of controller ensure a clear path into slot on mounting plate Fig 4D E 2 Ensure proper alignment of board to board connectors Fig 4E while pivoting controller toward door until two tabs on top snap securely into place on mounting plate Fig 4D CAU...

Page 30: ...asket top edge goes between plate and gasket 2 Carefully press bottom of cover toward door without pinching any wires 3 Secure the cover with a security allen wrench 6 Inside Cover Installation Fig 5B Note location of installed ferrite bead IN220 PoE and excess wires Fig 6A D B IN120 WIFI 1 Once controller is securely in place place 6 AA alkaline batteries in the compartment being care ful to alig...

Page 31: ...rness to eliminate issues b The key should unlock the outside lever and the lever should rotate freely For units without a keypad add card using LCT software and then test For units with a keypad add pin and card using LCT software and then test 2 LED signaling After using a valid credential a green flash followed by motor unlock indicates normal operation lock unlocks After using a valid credenti...

Page 32: ...oor closers exit devices electro mechanical products and access control systems for new construction renovation and replacement applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2016 2019 2021 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express writt...

Reviews: