A7857A • 800-810-WIRE (9473) • www.sargentlock.com
G1-PA & G1-TA Programming
Important
Profile Series v.G1.5 controllers replace v.G1 controllers. Product is still ordered as “G1-” prefix.
Controllers are labeled “G1.5”.
To determine programming steps for your lock:
If your controller has a G1.5 label and no keypad (proximity only),
then use the programming below.
In a Prox Only (PA) or RF Technology & Prox (TA) configuration, all programming
must be completed using SofLink™ Plus Software. The Software includes a con-
venient Software User’s Manual (A7771), to be used as
a programming guide.
Reprogramming
Note 1: With a proximity card, fob, tag or RF Fob Card selected as a "CommEnable" User, presenting the "CommEnable"
card to the lock will initiate communications after performing Step 2 (above) without the need to press the
CommEnable button.
Note 2: After performing "first time programming" procedure,
create a CommEnable card to facilitate
communications from then on.
PDA Response: "Please enter your
communications code at the door"
The PDA will begin transferring
(0-100%) of the door data to the lock.
-
+
-
+
-
+
-
+
+
-
+
-
G1.5 - PA
Comm Enable
Push Button
4
To program the lock for the first time (only), the following steps are required.
1. Using SofLink Plus software, Hotsync door information to PDA.
2. On PDA - select “Imp/Exp”
“Do NOT click OK at this point”
3. Wake up the PA or TA lock by presenting an HID Credential (or by
depressing an RF Fob).
4. Within a couple of seconds, press and hold the PA or TA controller
CommEnable push button (below batteries) for 2 seconds, then release
the button.
5. On the PDA, click “OK”.
6. If there was an error, check connections and repeat process starting at Step 2.
Note: *The Card will NOT actuate the lock for 45 seconds from the start of the
downloading process. After this time expires, the card will function as defined by
its User Type.
Lock Response: Audible beep
Keypad Programming Instructions for the Profile Series v.G1.5 Lock
To Enable/Disable A User
99# Master Code*
Yellow LED blinks
56# 0# (Enable) or 1# (Disable)
(User Number 03-2000)#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
To Delete A User
99# Master Code*
Yellow LED blinks
50# 1# (User Number 04-2000)#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Status Indicators
3 very rapid beeps after User Code entered - Invalid User Code
4 long beeps after User Code entered - Low Battery Indication
4 long beeps after User Code entered, 4 more long beeps - Voltage too low to operate. Enter Master or Emergency Code
to gain 1 entry
1 beep after User Code entered - Disabled user
4 beeps after User Code entered - Deadbolt thrown
3 beeps after User Code entered - User lockout
Alternating red/green LED — Awaiting second entry of Code/Card, Tag or Fob user