Copyright © 2020, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
05/31/20
SE LP10 Mortise Lock
A8113H • 800-810-WIRE (9473) • www.sargentlock.com
14
6 Install Inside Mounting Plate
NOTE: Feed mortise connectors and door harness through the
corresponding hole on the mounting plate.
A. Attach the mounting plate using two (2) #8 x 1/2”
lower
screws (Fig. 6). Feed bottom left screw through green/yellow
ground wire ring terminal. Install screw. Ensure that green/yel-
low wire points toward top of door in order to avoid interfer-
ence with escutcheon.
B. If fire kit is not being used, install (2) #8 x 1/2” in
upper
mounting plate holes.
Fig. 5A
A. For fire-rated doors only
, install reader backplate and fire shield to door using
two (2) #8-18 x 5/8” Phillips flat head self-drilling screws (Fig. 5A).
B. For exterior doors, install reader backplate and gasket using two (2) #8-18 x 5/8”
Phillips flat head self-drilling screws (Fig. 5B).
C. For non-fire rated interior doors, no fire shield or gasket is required; simply install
backplate using two (2) #8-18 x 5/8” Phillips flat head self-drilling screws.
Reader
Backplate
Fire Shield
Outside of Door
5 Install Reader Backplate and (Optional*) Fire Shield or Gasket
Fig. 5B
Gasket
(for exterior doors)
(for fire-rated doors)
*For non-fire rated interior doors,
no fire shield or gasket is required
(2) #8 x 5/8” Phillips flat head
self-drilling screws
Inside of
Door
Fig. 6