SE LP10 Mortise Lock
A8113H • 800-810-WIRE (9473) • www.sargentlock.com
15
Detail
Reader
Harness
Fig. 7B
A. Fit trim bezel around the reader. Ensure access hole in the bezel aligns
with screw hole on reader. The reader should be mounted so the holes face
bottom of door (Fig. 7A).
B. Align top of reader with top of backplate. Pivot reader down until seated.
Guide wires as needed to avoid pinching.
C. Secure the reader with (1) #6-32 x 3/8” Phillips or anti-tamper security torx screw
to the mounting plate (Fig. 7B).
7 Installation of SE LP10 Reader and Trim Bezel
!
Fig. 7A
Observe precautions for handling electrostatic sensitive devices.
!
!
Reader
Module
If the SE LP10 reader is installed with a module (Fig. 7A), make sure
that the reader is powered down when inserting/removing the module;
i.e., do not “hot-plug” (remove/insert while reader is powered) module
as it may damage the reader.