05/31/20
Copyright © 2020, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
SE LP10 Mortise Lock
A8113H • 800-810-WIRE (9473) • www.sargentlock.com
19
A. Rotate the inside rose first counter clockwise
to seat the threads then clockwise to
securely tighten.
B. Slide lever handle onto spindle until fully
seated. Be sure handle is horizontal and
facing the hinge side of the door. Push lever
onto spindle so minimum gap is visible.
C. Tighten the set screw securely with
a 1/8” hex wrench.
D. Before closing the door, test that the
lever is functional and ensure
smooth operation of the
latchbolt and deadbolt.
Inside of Door
13 Install Inside Rose and Inside Lever Assembly
Fig. 13A
Fig. 13B
Set Screw
Inside Lever
Spindle
Rose
Attach front plate with (2) 8-32x1/4” flat head screws and tighten securely.
Fig. 14
(2) 8-32x1/4”
Flat Head Screws
Outside of Door
14 Attach Front Plate