background image

6

1-800-727-5477 • www.sargentlock.com

A8257E 4/22

7800 and 8200 Series Mortise Lock

Installation Instructions

Used with Sectional Trim and V Series Indicators

Copyright © 2019, 2020, 2021, 2022, SARGENT Manufacturing Company. All rights reserved. Reproduction in 
whole or in part without the express written permission of SARGENT Manufacturing Company is prohibited. Patent 
pending and/or patent www.assaabloydss.com/patents.

Installation, continued

5

g

Install Cylinders

Cylinder

Cylinder 
Clamp 
Screw

Figure 11 

 

Incorrect

Key and cylinder must be rotated as shown.

Correct

Figure 12 

  

Figure 13 

 

Lock screw

Outside front

#8-32 x 1/4" 
screws

Lock 
screw

1.  Thread cylinder into lock until flush with escutcheon  surface. (Figure 11)

•  Pull key slightly out of cylinder to help thread into lock body.

2.  Tighten cylinder clamp screw with #2 Phillips screwdriver.

•  Check operation and adjust if necessary.

Notes: 

• 

 SARGENT logo must be horizontal and on top. (Figure 12)

• 

 If double cylinder function is used, repeat steps 1 and 2 for second 
cylinder.

• 

 Removable Core or Interchangeable Core cylinders 
require a control key (key stamped with C) to remove and 
install the core.  This is not provided standard; it must be 
requested separately.  If requesting 1-bitted control key, 
specify 113511 cut. 

h

Install Outside Front

1.  Tighten the two (2) lock screws completely: (Figure 13)

2.  Attach outside front with two (2) flat head screws #8-32 x 1/4". 

i

Perform Functional Check

DO NOT FORCE if resistance is encountered during functional 
check. Refer back to Rehanding Indicator (if required) section to ensure 
correct handing. Rehand if necessary.

1.  Insert key into cylinder (if present) and rotate:

•  Ensure there is no friction against lock case or any other 

obstructions.

2.  Check key retracts latch:

•  Key should rotate freely.

3.  Throw deadbolt (if present): 

•  Check key retracts both deadbolt and latch.

4. Test 

levers:

•  Confirm latch and deadbolt (if installed) retract.

5.  Verify indicator displays correct status when locked and unlocked.

Summary of Contents for SARGENT7800 Series

Page 1: ...part without the express written permission of SARGENT Manufacturing Company is prohibited Patent pending and or patent www assaabloydss com patents WARNING This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov Attention Installer Improper installation may result i...

Page 2: ...e screwdriver 1 8 Allen Wrench 3 32 Drill bit T 20 Torx Screw with Tamper Pin Driver Indicator Variants 2 Depending on function and option ordered indicators are provided in the following variations these instructions detail how to install with cylinder however other variations follow similar instructions Figure 1 Contact factory for any questions Figure 1 Coin Turn For installation on outside of ...

Page 3: ...rs are handed correctly using Spindle Cam Position chart Figure 3 If they are handed correctly skip to Step 5 Prepare Door If they are not handed correctly 1 Remove retaining pad and spindle cam from assembly Figure 4 2 Position spindle cam in correct direction for door hand Figure 3 Important For thumbturn indicators make sure thumbturn is positioned in the 12 o clock direction as shown Figure 5 ...

Page 4: ...6 3 Temporarily hand tighten two 2 lock screws 12 x 1 1 4 wood screws or 12 24 x1 2 machine screws Notes Keep door open until installation is complete If installing lever onto only one 1 side of door 36 function see separate instruction sheet A7028 c Prepare Door for Indicator Template Guide Mark holes with pencil Figure 7 Control Hub 1 Insert template guide into control hub on side where indicato...

Page 5: ...e assembly through door and lock body and hold Figure 8 2 Slide inside spindle into lock body hub 3 Slide adapter and plate assembly over spindle 4 Secure with two 2 8 32 x 5 8 screws 5 Install inside rose onto adapter plate 6 Install inside lever on adapter plate Secure with set screw 1 Screw indicator mounting plate to door with four 4 6 x 3 8 sheet metal screws Figure 9 2 If indicators are bein...

Page 6: ...es SARGENT logo must be horizontal and on top Figure 12 If double cylinder function is used repeat steps 1 and 2 for second cylinder Removable Core or Interchangeable Core cylinders require a control key key stamped with C to remove and install the core This is not provided standard it must be requested separately If requesting 1 bitted control key specify 113511 cut h Install Outside Front 1 Tigh...

Page 7: ... 81 0742 x finish 2 Indicator Window 81 0811 1 3 Indicator Display Assembly Green Unlocked Red Locked 82 5602 1 Indicator Display Assembly Green Vacant Red Occupied 82 5603 Indicator Display Assembly Green Unlocked Icon Red Locked Icon 82 5604 Indicator Display Assembly White Unlocked Red Locked 82 5605 Indicator Display Assembly White Vacant Red Occupied 82 5606 Indicator Display Assembly White U...

Page 8: ...NING This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov A8257E 4 22 ...

Reviews: