Securitron

®

 B100  

Secondary Voltage Module

Quick Start Guide

Specifications and more details  

found in the full manual here.  

(Downloadable pdf)

Overview

DC IN Connectors (J1 & J4) –

 These fastons are the input to the Securitron 

B100. Either faston may be used as the input. Two connections are 

provided to allow this voltage to pass through to other accessory boards 

in the system. This input voltage must always be at least 3 volts above the 

output voltage setting for the Securitron B100 to maintain its output.

DC OUT Connectors (J2 & J5) –

 These fastons are the output 

of the Securitron B100 for connection to other accessories in 

the system. This output may be considered as an equivalent 

to the main output of an Securitron AQL power supply. Either 

or both DC OUT fastons may be used in the system.

Ensure there are no other voltage sources 

connected to the buss before powering 

the system or damage WILL occur.

BR Connectors (J3 & J6) –

 The DC Common buss in the 

system. All boards in the system must have their BR 

fastons wired together for proper operation.

DC IN LED (D1) 

(BLUE/GREEN) 

 This LED indicates the availability 

of voltage on the DC IN Buss. When voltage is available on the 

buss, the LED is lit. This LED is bi-color and indicates the input 

voltage as follows: GREEN – 12 V Input | BLUE – 24 V Input

NOTE

 LED colors are range based. Voltage Less 

than 13 V will show Green. Voltage above 20V 

will show Blue. Voltage between 13 and 20 may 

show either voltage or a combination Green & 

Blue. Always verify voltage with a voltmeter

FAULT LED (D7) 

(YELLOW)

 – 

This LED lights when the 

Securitron B100 detects a fault condition. This fault condition 

also transmits to the Securitron AQL power supply. Fault 

conditions detected include ruptured output fuse, no output, 

output overload, or output voltage out of regulation.

FlexIO Connectors (JP1 & JP2) –

 These connectors allow the fault status of 

the Securitron B100 to be transmitted to the Securitron AQL power supply 

and pass the FlexIO buss on to other accessory boards in the system.

Output Voltage Selection (JP3 & VR1) –

 This jumper selects the 

output voltage for the Securitron B100 and the potentiometer 

sets the output voltage when in the adjustable range. In 

adjustable range, voltage may be set from 5 to 18 VDC.

Possible jumper settings are as follows:

• 

12 V Out JP3 Position 1

• 

Adjustable Output JP3 Position 2

The VR1 potentiometer will have no effect unless 

the jumper is set for the adjustable range

NOTE

 that the input must be at least 3 V above the output voltage 

setting or the Securitron B100 will display a fault condition. It may be 

helpful to temporarily set the input power supply to 24 V (Remove load 

devices first) before setting the Securitron B100 output voltage.

DC

 

Output –

 This is the output terminal strip. This terminal strip is 

nonremovable and accepts wire sizes from AWG 12 – AWG 22. The 

terminals are labeled on the PC board by the terminal strip.

Output Fuse (F1) –

 This fuse protects the DC Output 

terminals. It does not protect the DC OUT faston.

10 

DC OUT LED (D4) (GREEN) –

 This LED indicates the availability of voltage 

on the DC OUT Buss. When voltage is available on the buss, the LED is lit. 