6.4  DOOR PROP ALARM FUNCTION 
This function provides enhanced security at the door 
by creating an alarm signal any time the door is left 

open too long while being used for entry or exit.  
With the function enabled, select a relatively long 
door open time
 (see Section 4.5 to set timer).  You 
will then need a door switch whose contacts open 
when the door opens.  To wire the door switch, follow 

the drawing to the right.  You will give up the function 
of disabling either the Hard code or all the User codes (see Section 7.2).  Put the unit into 
program mode and enter 8-2 to put this feature on the HCD terminal or 8-3 to put it on 
the UCD terminal
.  You will see the two flash confirmation.  Then, exit program mode.  The 
respective input terminal will have its meaning redefined.  You will also give up the opportunity 
to implement a doorbell or other use of the programmable relay. 

 
Now, when a code is entered (or the REX input is used), the door will release for the relatively 
long period of time programmed.  If the door is not opened at all, the lock will resecure when 
the set time expires and nothing further will happen.  If the door is opened and recloses before 
the time expires, it will resecure immediately upon closure.  This is called anti-tailgating and 

means that although you have selected a long release time, a second person will not be able to 
use the door after a first person has, because the door resecures immediately upon reclosure.  If 
the door remains open for a longer period of time than is set on the timer, the programmable 
relay will switch and will remain energized until the door closes or the keypad is used again.  
Note that if you are using the programmable relay for another function you can enable anti-

tailgating alone (no alarm signal) as is described in Section 7.4. 
 
Connection from the programmable relay is generally not 
made to an alarm system, as if an alarm system is active 
on the door, you can get the same “door open too long” 
signal more simply by using the second pole of the lock 

control relay to shunt the door switch (see Section 7.3).  
Generally, you mount a Sonalert on the CPU board 
enclosure.  It will sound if the door is left open too long and this will act as a prompt for 
someone near the door to close it.  Sonalerts operate on 12-24 VDC so the wiring shown on the 
drawing to the right should be used. 

 
To terminate this function and return the HCD or UCD input to its standard use (and return the 
programmable relay to the doorbell function), put the unit into program mode and enter 8-4.  
You will see the two flash confirmation.  Then, exit program mode. 
 

6.5  NIGHTLIGHT FUNCTION 
When this function is selected, the act of touching any key will operate the programmable relay 
for five seconds.  This may be used to turn on a lamp directed at the Keypad at night so that the 
person using the Keypad can see to enter the code.  Put the unit into program mode and enter 
7-7
.  You will see the two flash confirmation.  Then, exit program mode. Note that selection of 

this option means you give up the opportunity to implement a doorbell or other use of the 
programmable relay. 
 
To return the programmable relay to factory set (doorbell) function, put the unit into 
program mode and enter 7-8.  You will see the two flash confirmation.  Then, exit program 
mode. 

 
7.  ADDITIONAL HARD WIRED OPTIONS 
7.1  DUAL PAD OPERATION 
If keypad control from both sides of the door is desired, two keypads can be connected to 
one CPU Board
.  Simply put the colored wires from both keypads into the appropriate terminals 

on the CPU Board such that 2 wires are in each terminal.  Either keypad will then be able to 
release the lock and both keypads will beep and illuminate their LED's when either one is used.  
Two is the maximum number of keypads that can be connected to one CPU Board.  Note that in 
the unusual case where both keypads are being used simultaneously, the door will not release as 
the sequence will certainly be disturbed.  Only one keypad may be used at a time.  Be sure you 

SRC

UCD HCD

CONNECT A DOOR
SWITCH WHICH
OPENS WHEN THE
DOOR OPENS TO
UCD OR HCD
DEPENDING ON WHICH
COMMAND YOU CHOOSE

DOOR SWITCH

 

CX

NOX

DC I

N

 /

O

U

T

+

SONALERT

AUDIBLE DOOR PROP ALARM

 

Summary of Contents for Securitron DK-26

Page 1: ...500 16900 Rev D 12 11 ASSA ABLOY the global leader in door opening solutions MODEL DK 26 DIGITAL KEYPAD SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Securitron Magnalock Corp www securitron com Tel...

Page 2: ...PROGRAMMING Page 8 SECTION 4 2 KEYPAD CHANGEABLE PROGRAMMING Page 9 SECTION 4 2 1 CHANGING THE USER AND PROG CODE FROM KEYPAD Page 10 SECTION 4 2 2 ADDING MULTIPLE USER CODES Page 10 SECTION 4 3 MAST...

Page 3: ...eypad is pulled down firmly on to the screw A 3 8 10MM hole is then drilled for the cable After the cable has been pulled through the final screw secures the keypad to the wall Note finally that a bla...

Page 4: ...which could cause the microprocessor to malfunction The MOV should be spliced into the lock power wires as close to the lock as possible Some DC electric locks have internal kickback protection includ...

Page 5: ...om an AC transformer when the DK 26 is used Select a transformer of the same voltage as the lock 12 or 24 The CPU board converts the input AC to DC to operate the lock Make sure the capacity of the tr...

Page 6: ...DK 26 and the lock The DK 26 does not require regulated power but certain specialized electric locks do so follow the rule of matching the power supply to the requirements of the lock DC locks come i...

Page 7: ...to send power to the lock Figure 6 shows how to add external contacts for non timed remote release of the lock for both lock types FIG 6 ADDING EXTERNAL CONTACTS FOR FAIL SAFE AND FAIL SECURE LOCKS NC...

Page 8: ...while its normally open contacts activate the DK 26 In effect the lock is released twice Note that the NC contacts are placed in the circuit before the DK 26 s lock control relay This is to aid possi...

Page 9: ...programming in a situation where the end user is not likely to ever change the code or at least that changes would be rare Fixed programming can be used in lower security traffic control applications...

Page 10: ...ixed code programming 4 2 KEYPAD CHANGEABLE PROGRAMMING In this application two codes are programmed into the DK 26 The first called the Program code acts as a password which allows changing the User...

Page 11: ...ately by a new 2 7 digit User code Wait 5 seconds Note two red LED flashes for confirmation note rapid yellow flashing LED returns Press Bell key to terminate program mode or wait 30 seconds Re enter...

Page 12: ...code The unit could not be put into program mode from the keypad The DK 26 however avoids this problem by rejecting any code that is a subset of another code in memory It signals this rejection by sh...

Page 13: ...y by entering a User code and then secured all night by entering a User code again When you have enabled toggle mode activation of the REX input will successively energize and deenergize the lock cont...

Page 14: ...inary operation must be via one or more User codes see Section 4 2 for programming Program the Hard code as your duress code see Section 4 1 Put the unit in program mode and enter 7 5 You will see the...

Page 15: ...e simply by using the second pole of the lock control relay to shunt the door switch see Section 7 3 Generally you mount a Sonalert on the CPU board enclosure It will sound if the door is left open to...

Page 16: ...e terminals 7 3 ALARM SYSTEM SHUNTING The DK 26 s lock control relay is of the double pole double throw type Note that in all the other drawings in this manual we show only one of the poles being used...

Page 17: ...K 26 is often used with Securitron s Touch Sense Bar and magnetic lock The following drawing shows wiring for this particular configuration Note that the REX input is not used Since touching the bar o...

Page 18: ...timer Two digit codes must be entered from 01 to 99 seconds Default is 5 seconds Entering 00 sets toggle mode APPENDIX B TROUBLESHOOTING Note first that the DK 26 replaces older Securitron keypads the...

Page 19: ...nt through the PolySwitch trips it so that it clamps the current down to roughly 100 mA The PolySwitch will continue to clamp until all power is removed for about 5 seconds It is not enough to correct...

Page 20: ...ace the keypad for full operation PROBLEM Unit beeps when keys are pressed but does not accept programming If the problem occurs on initial installation usually it s caused by misunderstanding the pro...

Page 21: ...ry slot 45 You test the code by re entering 4 5 1 2 and the door opens because the sequence includes the real code 1 2 Later it will be noticed that the door is opening on 1 2 as this is such a simple...

Page 22: ...a fail secure lock is operated from the same supply as the DK 26 When the lock is energized it may draw too much power for the power source This reduces the voltage and these voltage swings can crash...

Page 23: ......

Reviews: