Description 

Model Securitron EEB2

 is a two-inch square, exit button, 

mounted on a stainless steel, single gang key plate. 

Model Securitron EEB3N

 is a rectangular exit button, 

mounted on a 1 3/4" stainless steel narrow stile key plate.
Both Securitron EEB2 and EEB3N have a 3A switching 

capacity and a timer set for 30 seconds. These units are 

intended only for release of a magnetic lock from the inside 

of a door. When the button is pressed, the lock releases 

for 30 seconds. If pressed again during the 30-second 

lock release period, the unit will “retrigger” starting a 

new 30-second lock release period. These buttons are 

specifically intended for installation on access controlled 

egress doors, as described in the International Building Code 

(IBC).  Check your jurisdiction for applicable IBC codes. 
A motion detector, such as the Securitron Model XMS, 

is the primary means of magnetic lock release on the 

door. The Securitron EEB2 or EEB3N exit button is 

employed as a backup means of releasing the lock in 

case of a problem with the motion detector. It should 

be noted that the exact release time will vary with 

temperature, but it will not be less than 30 seconds.

UL294 Access Control 

Performance Levels

The following are the UL294 access 

control performance levels:

• Destructive Attack

 = Level 1

• Line Security

 = Level 1

• Endurance

 = Level 1 (6,000 cycles)

• Standby

 

Power

 = Level 1

Securitron EEB2

Securitron EEB3N

Summary of Contents for Securitron EEB2

Page 1: ...gger starting a new 30 second lock release period These buttons are specifically intended for installation on access controlled egress doors as described in the International Building Code IBC Check your jurisdiction for applicable IBC codes A motion detector such as the Securitron Model XMS is the primary means of magnetic lock release on the door The Securitron EEB2 or EEB3N exit button is emplo...

Page 2: ...on EEB2 and EEB3N draw no current when at rest and only draw 28 mA at 12 VDC or 38 mA at 24VDC when releasing the lock 1 WIRE the Securitron EEB2 or EEB3N in accordance with Diagram 1 2 and 3 CAUTION The Securitron EEB2 and EEB3N can be damaged if operated on 24 VDC with the jumper in place or operated on a power supply different than what is operating the magnetic lock Red 12 V or 24 V 0 V DC Neg...

Page 3: ...rt onto the front of switch 7 ENSURE that the text on the insert is correctly reading to the keyplate and PLACE the matching color lens on top of insert 8 PRESS around all edges of the lens until it snaps in place 9 DEPRESS lens several times to ensure smooth operation and the lens is not binding 10 With the terminals upward INSERT the contact block back into the back of the switch at the 11 00 o ...

Page 4: ...reet Ste 102 Phoenix AZ 85044 USA 4 of 4 Changing the Alternate Lens on the Securitron EEB3N 1 While holding keyplate GRASP the top and bottom of the lens and PULL straight out from the keyplate 2 PLACE a new lens over the switch face and ENSURE the text on the lens is correctly reading to the keyplate 3 PRESS completely until it snaps into place 4 DEPRESS the lens several time to ensure smooth op...

Reviews: