Mounting  

the Back Plate

1. 

Level and mark the desired 

placement. Clean the mounting 

surface with provided 

alcohol swab. Remove 

reader from backplate.

2. 

Cut the VHB tape into 

two pieces and apply tape 

as shown in Diagram 3. 

Mount backplate to marked 

location and apply pressure 

to activate tape adhesive.

NOTE: 

VHB tape is intended to be 

used on glass and non-porous metal 

surfaces. For all other surfaces, use 

an appropriate adhesive and follow 

the manufacturer’s instructions.

3. 

Install batteries (Diagram 4) .

4. 

Secure reader to backplate.

NOTE: 

Ensure reader is fully seated 

against the backplate and the screw hole 

is properly aligned before securing.

Micro USB Port

For emergency power & local 

(hard wired) firmware updates, 

use micro USB port located on 

the side of the R100 reader.

Diagram 3: 

VHB Placement & Mounting

Diagram 2: 

Mark Placement & Remove Back Cover

Diagram 4: 

Install Batteries & Secure Reader

Diagram 5: 

Micro USB

Summary of Contents for Securitron R100 Aperio

Page 1: ... Lithium 1 5 Volts V Battery Life 50 000 cycles All battery life claims are approximate and based on a set configuration profile Battery performance is based on pre defined system settings such as battery chemistry and battery model used credential presentation settings LED buzzer UHF polling period UHF status intervals and operations per day Actual battery performance will vary and depends on the...

Page 2: ... non porous metal surfaces For all other surfaces use an appropriate adhesive and follow the manufacturer s instructions 3 Install batteries Diagram 4 4 Secure reader to backplate NOTE Ensure reader is fully seated against the backplate and the screw hole is properly aligned before securing Micro USB Port For emergency power local hard wired firmware updates use micro USB port located on the side ...

Page 3: ... Red Flashes Error in Lock Continuous Yellow Flashes 25 sec every 5 seconds Low Battery Continuous Red Flashes 25 sec every 5 seconds Dead Battery Aperio LED HUB Codes Steady Green Online Steady Green 1 ONE Red Flash Lock Offline Steady Green 2 TWO Red Flashes Access Control Offline Steady Green 3 Three Red Flashes Access Control Lock Offline Flashing Yellow UHF Communication For placement of hub ...

Page 4: ...ipement génère utilise et peut émettre des fréquences radio et s il n est pas installé et utilisé conformément ment aux instructions du fabricant peut causer des interferences nuisibles aux communications radio Rien ne garantit cependant que l interférence ne se produira pas dans une installation particulière Si cet équipement provoque des interférences nuisibles à la réception radio ou de télévis...