background image

of 4

Connecting the Hub

The following applies only to Aperio 

factory paired kits with AH20 Hubs.

1. 

Connect the Wiegand D1, D0, 

red, and green LED signals.

NOTE: 

The Green LED input is used to grant 

access to the cabinet lock. If the Green LED 

signal is not available to indicate approved 

access, the approval input can be activated 

by a relay with “NO” attached to Green LED 

and “C” to GND. The Red LED input is used to 

indicate access denied. If the RED LED signal 

is not connected, the lock will flash RED three 

times when a non-approved card is presented 

indicating loss of connection to the hub 

rather than access denied. Any other codes 

may be reference on the LED reference card.

LED Codes

Aperio LED LOCK Codes

(1) ONE Yellow Flash

Card read

(1) ONE Green Flash

Access Granted

(5) FIVE Yellow (1) ONE Red

           

Force Closed  

(in open mode)

Continuous Yellow Flashes

(.25 sec every second)

                         

Comhub busy

(1) ONE Red Flash

Access Denied

(AC Online)

(3) THREE Red Flash

   

Access Denied

(AC Offline)

Continuous Red Flashes

(.125 sec every second)

                 

Lock is Blocked

(when closing)

(10) TEN Red Flashes

                 

Error in Lock

Continuous Yellow Flashes

(.25 sec every 5 seconds)

                            

Low Battery

Continuous Red Flashes

(.25 sec every 5 seconds)

                            

Dead Battery

Aperio LED HUB Codes

Steady Green

Online

Steady Green  

+ (1) ONE 

Red Flash

Lock Offline

Steady Green  

+ (2) TWO 

Red Flashes

Access Control 

Offline

Steady Green  

+ (3) Three 

Red Flashes

Access Control 

& Lock Offline

Flashing 

Yellow

 

 

 

 

 

UHF 

Communication

For placement of hub, see AH20/AH30  

Installation Instructions

Aperio Hub Specifications

•  Approvals 

CE, ETL, FCC, IC, C-Tick

•  Safety & Emissions 

FCC 47CFR Part 15 subpart B and subpart C; 

IC RSS-210 EN ETSI 301 489-17 v2.1.1; ENETSI 

300 328 v1.7.1; EN 60950-1 ed.2 2007

•  Dimensions

  82mm x 82mm x 37mm

•  Power

 

Supply

  8-24 VDC

•  Current

  250 mA minimum

•  Internal

 

Antenna

  2 cross polarized dipoles

•  External Antenna (Part No. EXT-10-ANT) 

One reverse polarity SMA external antenna 

connector. Optional antenna type dipole 

with max antenna gain of 3.9dBi

•  Radio

 

Standard

  IEEE 802.15.4(2.4GHz) 

– 15 channels (11-25)

•  Encryption

 (

RadioCommunications

)   

AES 128 bits

•  Wireless

 

Operating

 

Range

  Up to 50 ft

•  Receiver Sensitivity

 

-100dBm 20% PER

•  Wireless

 

Transmit

 

Power

  10 d Bm/MHz

•  Class

 

of

 

Protection

  IP 20

•  Operating

 

temperature

  

41°F to 95°F  [5°C to 35°C]

•  Humidity

  < 95% non-condensing

•  Status

  LED (red/green/yellow)

Summary of Contents for Securitron R100 Aperio

Page 1: ... Lithium 1 5 Volts V Battery Life 50 000 cycles All battery life claims are approximate and based on a set configuration profile Battery performance is based on pre defined system settings such as battery chemistry and battery model used credential presentation settings LED buzzer UHF polling period UHF status intervals and operations per day Actual battery performance will vary and depends on the...

Page 2: ... non porous metal surfaces For all other surfaces use an appropriate adhesive and follow the manufacturer s instructions 3 Install batteries Diagram 4 4 Secure reader to backplate NOTE Ensure reader is fully seated against the backplate and the screw hole is properly aligned before securing Micro USB Port For emergency power local hard wired firmware updates use micro USB port located on the side ...

Page 3: ... Red Flashes Error in Lock Continuous Yellow Flashes 25 sec every 5 seconds Low Battery Continuous Red Flashes 25 sec every 5 seconds Dead Battery Aperio LED HUB Codes Steady Green Online Steady Green 1 ONE Red Flash Lock Offline Steady Green 2 TWO Red Flashes Access Control Offline Steady Green 3 Three Red Flashes Access Control Lock Offline Flashing Yellow UHF Communication For placement of hub ...

Page 4: ...ipement génère utilise et peut émettre des fréquences radio et s il n est pas installé et utilisé conformément ment aux instructions du fabricant peut causer des interferences nuisibles aux communications radio Rien ne garantit cependant que l interférence ne se produira pas dans une installation particulière Si cet équipement provoque des interférences nuisibles à la réception radio ou de télévis...

Reviews: