Concept 

 
There are two ways we can configure the TCP/IP – RS232 adaptor. 

2.2

 

Configuring the TCP/IP – RS232 Adaptor via web browser 

Open your web browser and type 

http://192.168.2.1

 and click enter. 

The User Log-in screen appears. 
Default ID: admin 
Default Password: system 

 

 
The setup screen will then appear. 

 

 
First we will change the RS232 settings, therefore we will select UART at the left side of the screen. 

 

We must change the following settings: 
Baudrate: change to 115200 
Silent time: If selected, please remove the selection. 
If these settings have been made, click on the Update button. 

Summary of Contents for SMARTair Mini Updater

Page 1: ...SMARTair Mini Updater...

Page 2: ...1 Adding the TCP IP RS232 adaptor in the VCOM software 5 2 3 2 Now we can setup the virtual comport for the mini updater 8 4 Setting up the Mini Updater software 10 5 Setting up Windows to start up t...

Page 3: ...rt 3050 the firewall needs setup accordingly You will need an IP address for the Mini updater before you start setting up the mini updater 2 Setting up the TCP IP RS232 Adaptor 2 1 Connecting the TCP...

Page 4: ...ick enter The User Log in screen appears Default ID admin Default Password system The setup screen will then appear First we will change the RS232 settings therefore we will select UART at the left si...

Page 5: ...r via the VCOM program Always use the latest version of the VCOM program with a new installation or in case of problems Run the VCOMsetup exe program can be downloaded from the Tesa support website or...

Page 6: ...232 adaptor will be listed in the VCOM program We can now Configure the TCP IP RS232 adaptor by selecting the TCP IP RS232 adaptor and by clicking on the Configure Button Enter the Login and password...

Page 7: ...12 04 2016 7 Concept Scroll down to the UART section and change the Baudrate to 115200 and uncheck the Silent option if needed...

Page 8: ...n we click on the ADD button First select the correct TCP IP RS232 adaptor we which to setup and then we give the comport its number and click OK Make sure that the comport number is in an higher rang...

Page 9: ...pt In the VCOM program we will now see the COM Port in the COMM Mapping menu The TCP IP RS232 adaptor is now setup completely Now we can proceed installing the Mini Updater software and the link to th...

Page 10: ...ter by opening the Config ini file in notepad Right click on the Config ini file and select Open With and select notepad In the config ini file we change the COM port number to the number we defined i...

Page 11: ...12 04 2016 11 Concept You can now start the UpdateBox1 exe file If everything is configured correctly the UpdaterBox is running and displaying the correct Name of the Updater...

Page 12: ...tcut and place this in the Windows startup folder First we create the shortcut by right clicking on the UpdaterBox1 exe file and selecting create shortcut Change the name of the shortcut to the same n...

Page 13: ...abase Patch and the firewall settings TCP IP port 3050 must be open VCOM and the UpdaterBox must be running at all times 7 Reset the TCP IP RS232 adaptor to default 7 1 Reset without changing the IP a...

Page 14: ...r Open the adaptor and press the reset button Now apply the Power supply to the adaptor while pressing the reset button Keep the reset button pressed for about 10 seconds and then release the reset bu...

Reviews: