Rim Installation Instructions (Continued)

-

+

-

+

-

+

-

+

+

-

+

-

Security
screw

Security tool
01-0297 included

Battery keeper

Battery cover

- Polarity

+ Polarity

Bottom slots

Top tab

Tabs

Top slots

Step #6 Rail Assembly

Attach rail assembly according to exit installation instructions A6770

Fig. 4

Fig. 5

Fig. 6

Fig. 7

1. Place (6) “AA” batteries into

the compartment, being
careful to align polarity
properly (Fig. 5).

2. Install battery keeper clip

by inserting tabs into
bottom slots first (Fig. 6). To
remove keeper, pull on top
tab. For RF Technology
version refer to Section 9.

3. Attach battery cover to inside

escutcheon, making sure to
line up tabs with retaining
slots in battery cover. Secure
with security screw (Fig. 7).

Note: For RF

Technology versions

(G1-TU, G1-TP, G1-TA)

refer to Section 9 when

installing/removing 

battery keeper.

Summary of Contents for v.G1 Sargent

Page 1: ...t 2004 2008 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited FOR ASSISTANCE CONTACT SARGENT AT 800 727 5477 or www sargentlock com ...

Page 2: ...nterference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver ...

Page 3: ...on with Keypad Outside Motorized Trim Assembly Exit Device Inside Escutcheon with Circuit Board and Battery Pack 6 AA alkaline batteries Screw Pack Specifications Profile Series Rim Exit Latch 3 4 throw stainless steel Outside motor driven ET lever controlled by keypad Push bar retracts latch from inside Fire stop provided on all lever handle designs Profile Series exit devices furnished for 1 3 4...

Page 4: ...acturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Parts Breakdown 8877 8878 x ET x Lever Design Profile Series Rim Exit Device 5 1 7 6 12 11 14 13 X2 13 X2 13 15 2 9 3 5 4 18 X4 17 ...

Page 5: ...r G1 TU 52 2835 Inside Escutcheon Assembly Keypad Prox or Prox Only with RF Technology Controller G1 TA G1 TP 68 1396 Inside Escutcheon Housing Only 1 52 0175 Inside Escutcheon End Cap Only 1 52 2441 100 User Controller Assembly LK 1 52 2783 2000 User Controller Assembly G1 LU 1 52 2784 2000 User Controller Assembly G1 PA G1 PK 1 52 2786 2000 User Keypad Prox or Prox Only Controller Assembly w RF ...

Page 6: ...acturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Parts Breakdown 8977 8978 x ET x Lever Design Profile Series Mortise Exit Device 5 Door 9 3 5 15 19 X4 18 13 16 17 12 11 7 6 1 4 2 ...

Page 7: ...tcheon Assembly Keypad Prox or Prox Only with RF Technology Controller G1 TA G1 TP 68 1396 Inside Escutcheon Housing Only 1 52 0175 Inside Escutcheon End Cap Only 1 52 2441 Enclosure LK Assembly 1 52 2783 Enclosure G1 LU Assembly 1 52 2784 Key Pad Proximity Only Controller G1 PA G1 PK Assembly 1 52 2786 2000 User Keypad Prox or Prox Only Controller Assembly G1 TA G1 TP 52 2785 2000 User Keypad Onl...

Page 8: ...and outside door surface 2 Route harness through under cut of cylinder hole and out to other side of door 3 Place ET control onto door B Inside Trim 1 Route ET harness along track cutout for wood doors and access hole for metal doors 2 Mount exit chassis carefully DO NOT PINCH HARNESS WIRES 3 ET spindle will engage into the hub of exit device chassis 4 Secure chassis and ET with 2 1 4 20 x 2 3 8 f...

Page 9: ... self tapping screws Outside of door Wires connector go through fire stop plate Keypad ribbon cable connector 1 2 3 4 5 6 7 8 9 0 Step 4 Installation of Outside Escutcheon Insert connector and wires 1 For exterior applications gasket 68 1400 should be used to seal between escutcheon and outside door surface 2a For 12 fire rated devices feed keypad ribbon cable connector from outside of door throug...

Page 10: ...s to motor connector Fig 3 2 Place extra wire inside door hole and or outside escutcheon being careful not to pinch wires 3 Connectors go on only one way do not offset connector and be sure they are completely seated 4 Insert 8 32 x 1 1 4 screws through inside escutcheon and thread into outside escutcheon Straighten escutcheons and tighten securely Ground wire ET Motor harness Keypad harness Outsi...

Page 11: ...ts Top tab Tabs Top slots Step 6 Rail Assembly Attach rail assembly according to exit installation instructions A6770 Fig 4 Fig 5 Fig 6 Fig 7 1 Place 6 AA batteries into the compartment being careful to align polarity properly Fig 5 2 Install battery keeper clip by inserting tabs into bottom slots first Fig 6 To remove keeper pull on top tab For RF Technology version refer to Section 9 3 Attach ba...

Page 12: ...rify box label for size of exit device function and hand Step 1 Exit Hardware Door Prep Prep door according to Exit installation instructions A6705 and template 4641 metal and wood doors Step 2 Install Outside Trim Exit Chassis and Cylinder A Outside Trim 1 Slide mortise lock into door and securely fasten with 2 flat head screws 2 For exterior applications gasket 52 0263 should be used to seal bet...

Page 13: ...Lever Latchbolt Lever arm Inside of door 4 10 Wood screws or 10 24 machine screws B Exit Chassis 1 Route ET harness along track cutout for wood doors and access hole for metal doors 2 Mount exit chassis carefully Do not pinch harness wires 3 Position exit chassis on door with lever arm under rear section of mortise lock 4 Using 2 1 4 20 x 2 3 8 flat head screws attach chassis to ET control 5 Faste...

Page 14: ...upplied with them 2 Secure fire stop plate to door with 2 8 x 1 2 self tapping screws Mortise Installation Instructions Continued A Insert Wires and Connector 1 For exterior applications gasket 68 1400 should be used to seal between escutcheon and outside door surface 2 For 12 fire rated devices feed keypad ribbon cable connector from outside of door through gasket then fire stop plate 3 For non 1...

Page 15: ...cutcheon being careful not to pinch wires 3 Connectors go on only one way do not offset connector and be sure they are completely seated 4 Insert 8 32 x 1 1 4 screws through inside escutcheon and thread into outside escutcheon Straighten escutcheons and tighten securely NOTE For RF Technology versions G1 TU G1 TP G1 TA refer to Section 9 to install through bolt screws 5 Install batteries and cover...

Page 16: ...taining tabs during this process Press the two tabs away from the antenna board and lift the board off the mounting posts Insert the flat head through bolt and secure the escutcheon in place After tightening the top through bolt replace the antenna board by placing it on the mounting posts and pressing into the retaining tabs A Installation of the top through bolt screw To remove the battery keepe...

Reviews: