Mortise Installation Instructions (Continued)
1. Connect ground wire to terminal E3 (Fig. 1), keypad harness to controller (Fig. 2), and ET motor
harness to motor connector (Fig. 3).
2. Place extra wire inside door hole and/or outside escutcheon being careful not to pinch wires.
3. Connectors go on only one way, do not offset connector and be sure they are completely seated.
4. Insert #8-32 x 1-1/4" screws through inside escutcheon and thread into outside escutcheon.
Straighten escutcheons and tighten securely.
NOTE : For RF Technology versions (G1-TU, G1-TP, G1-TA) refer to Section 9 to install through bolt screws.
5. Install batteries and cover according to instructions on page 9.
Step #6 – Rail Assembly
Attach rail assembly according to Exit installation instructions A6705
1
2
3
4
5
6
7
8
9
0
*
#
Ground
wire
ET Motor
harness
Keypad
harness
Outside
of door
Inside
of door
For RF Technology
refer to Section 9.
Step #5 – Installation of Inside Escutcheon
Fig. 1
Fig. 3