background image

Copyright ©2020, 2021, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or 
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited

For technical support contact Yale

®

 at 800.438.1951 x5033 or support@yalelocks.com

3

Installation Instructions

8800 Series

Mortise Lock

80-8800-0016-000 11/21

2

Indicator Variants

4

Rehanding Indicator (If required)

Depending on function and option ordered, indicators are 
provided in the following variations, these instructions detail 
how to install with cylinder, however other variations follow 
similar instructions. (Figure 1) 

Contact factory for any questions.

Figure 1 

Cylinder - For 

installation 

on inside or 

outside of door.

Thumbturn - 

For installation 

on inside of 

door.

Coin Turn - For 

installation 

on outside of 

door.

No input / blank - 

For installation on 

inside or outside 

of door.

3

Lock Set Configuration

To re-hand lock, see instructions on lock body.

Spindle Cam Position for Locks with Deadbolt 

(*includes 8864 function)

Outside

 Indicator

Inside Indicator

Door Hand LH/LHRB

Spindle Cam Position for Locks without Deadbolt 

(*Does not include 8864 function)

Door Hand LH/LHRB

Note:
Stand on outside of locked door when determining door hand.

Next, verify inside and/or outside indicators are handed correctly, using 
Spindle Cam Position chart. (Figure 3) If they are handed correctly, skip to 
Step 5 “Prepare Door”. 

If they are not handed correctly:

1. 

Remove retaining pad and spindle cam from assembly. (Figure 4)

2. 

Position spindle cam in correct direction for door hand. (Figure 3)

Important:

• 

For thumbturn indicators, make sure thumbturn is positioned in the 12 
o’clock direction as shown. (Figure 5)

3. 

Slide spindle cam post into correct slot of display slide. (Figure 4)

4. 

Re-seat retaining pad into original position.

5. 

Return indicator to the vacant/unlocked position for installation.

Thumbturn 
Position

Figure 3 

Figure 4 

Retaining Pad

Spindle cam

Display 
slide slot

Door Hand RH/RHRB

Inside Indicator

Outside

 Indicator

Inside Indicator

Outside

 Indicator

Door Hand RH/RHRB

Outside

 Indicator

Inside Indicator

LH

Left Hand 

Hinges Left 

Open Inward

RH

Right Hand

 Hinges Right 

Open Inward

LHRB

Left Hand 

Reverse Bevel

Hinges Left

Open Outward

RHRB

Right Hand 

Reverse Bevel

Hinges Right 

Open Outward

Figure 5 

Figure 2 

Indicator spindle cams MUST be oriented correctly per lock function 
and door mounting location.

Verify hand and bevel of door. (Figure 2)

Scan this QR 

code for the Yale 

Indicator Handing 

Charts

Summary of Contents for Yale 8800 Series

Page 1: ...rt contact Yale at 800 438 1951 x5033 or support yalelocks com This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov WARNING 8800 Series Mortise Lock Used with Sectional Trim and V Series Indicators 80 8800 0016 000 11 21 WARNING Attention Installer Improper instal...

Page 2: ...0016 000 11 21 1 Tools Required 2 Indicator Variants 3 Lock Set Configuration 3 Rehanding Indicator if required 3 Installation 4 Prepare Door for Mortise Lock 4 Install Lock 4 Prepare Door for Indicator 4 Install Levers 5 Install Indicator Mounting Plate 5 Install Indicator Assembly 5 Install Cylinder 6 Install Outside Front 6 Perform Functional Check 6 Indicator Part List 7 3 2 4 TOC Table of Con...

Page 3: ... include 8864 function Door Hand LH LHRB Note Stand on outside of locked door when determining door hand Next verify inside and or outside indicators are handed correctly using Spindle Cam Position chart Figure 3 If they are handed correctly skip to Step 5 Prepare Door If they are not handed correctly 1 Remove retaining pad and spindle cam from assembly Figure 4 2 Position spindle cam in correct d...

Page 4: ...door Slide lock into door Figure 6 3 Temporarily hand tighten two 2 lock screws 12 x 1 1 4 wood screws or 12 24 x1 2 machine screws NOTE Keep door open until installation is complete 3 Prepare Door for Indicator Control Hub Guide Template Figure 7 Mark holes with pencil 1 Insert template guide into control hub on side where indicator will be used Figure 7 2 Slide indicator template over template g...

Page 5: ...erify lock is in unlocked state turn outside lever to confirm 2 Verify indicator is in vacant unlocked position 3 Assemble indicator assembly onto mounting plate Figure 10 4 Secure indicator assembly to door with two 2 machine screws Use 8 32 x 5 8 screw for top Use 8 32 x 3 8 screw for bottom 5 If indicators are being used on both sides of door repeat steps 6 1 through 6 3 for opposite side NOTE ...

Page 6: ... 7 2 for second cylinder Interchangeable Core cylinders require a control key to remove and install the core This is not pro vided standard It must be requested seperately Cylinder Cylinder Clamp Screw Key and cylinder must be rotated as shown 8 Install Outside Front 1 Tighten the two 2 lock screws completely Figure 13 2 Attach outside front with two 2 flat head screws 8 32 x 1 4 9 Perform Functio...

Page 7: ... 4000 Indicator Display Assembly Green Unlocked Icon Red Locked Icon 82 5604 4000 Indicator Display Assembly White Unlocked Red Locked 82 5605 4000 Indicator Display Assembly White Vacant Red Occupied 82 5606 4000 Indicator Display Assembly White Unlocked Icon Red Locked Icon 82 5607 4000 Indicator Display Assembly Green Ouvert Red Fermé 82 5684 4000 Indicator Display Assembly Green Libre Red Occu...

Page 8: ...sion of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited Patent pending and or patent www assaabloydss com patents U S A Yale Locks Hardware Address 225 Episcopal Road Berlin CT 06037 4004 Tel 1 800 438 1951 Fax 1 800 338 0965 yalecommercial com Canada ASSA ABLOY Door Security Solutions Canada Address 160 Four Valley Drive Vaughan Ontario L4K 4T9 Tel 1 800 461 3007 Fax 1 800 461 8989 ...