Installation
1
Prepare Door for Mortise Lock
Prepare door for function holes, size, and location
according to 7088-0006 door marker template, if not
already prepped.
Figure 6
Inside of door
Outside
of door
RH door
shown
Lock
Lock
Screws
2
Install Lock
1.
Verify strike location according to
template. Clean out door pocket and
door edge of debris.
2.
Make sure handing of lock matches
handing of door. Slide lock into door.
(Figure 6)
3.
Temporarily hand tighten two (2)
lock screws (#12 x 1-1/4" wood
screws, or #12-24 x1/2" machine
screws).
NOTE: Keep door open until installation is complete.
3
Prepare Door for Indicator
Control
Hub
Guide
Template
Figure 7
Mark
holes
with
pencil
1.
Insert template guide into control hub on
side where indicator will be used. (Figure 7)
2.
Slide indicator template over template guide.
Important: Make sure the template is properly centered
and aligned to ensure smooth indicator operation.
3.
Mark the four (4) hole positions indicated on tem-
plate.
4.
Remove guide and template.
5.
If indicators are being used on both sides of door,
repeat steps 3.1 through 3.4 for opposite side.
6.
Remove lock body.
7.
Drill four (4) marked holes with 3/32" diameter bit,
by 1/2" deep.
8.
Reinstall lock body and hand tighten screws.
NOTE: If retrofitting over an existing product, ensure door
surface is free of chips and debris around holes so