6
8800 Series
Installation Instructions
Mortise Lock
80-8800-0016-000 11/21
5
Installation, continued
7
Install Cylinder
Figure 11
Figure 12
Figure 13
1.
Thread cylinder into lock until flush with indicator
escutcheon surface. (Figure 11)
•
Pull key slightly out of cylinder to help thread into
lock body.
2.
Tighten cylinder clamp screw with #2 Phillips
screwdriver.
•
Check operation and adjust if necessary.
Notes:
•
Yale logo must be horizontal and on top. (See
Figure 12)
•
If double cylinder function is used, repeat steps 7.1
and 7.2 for second cylinder.
•
Interchangeable Core cylinders require a control
key to remove and install the core. This is not pro-
vided standard. It must be requested seperately.
Cylinder
Cylinder
Clamp
Screw
Key and cylinder must be rotated as shown.
8
Install Outside Front
1.
Tighten the two (2) lock screws completely:
(Figure 13)
2.
Attach outside front with two (2) flat head screws
#8-32 x 1/4".
9
Perform Functional Check
DO NOT FORCE if resistance is encountered during
functional check. Refer back to Rehanding Indicator (if
required) section to ensure correct handing. Rehand if
necessary.
1.
Insert key into cylinder (if present) and rotate:
•
Ensure there is no friction against lock case or any
other obstructions.
2.
Check key retracts latch:
•
Key should rotate freely.
3.
Throw deadbolt (if present):
•
Check key retracts both deadbolt and latch.
4.
Test levers:
•
Confirm latch and deadbolt (if installed) retract.
5.
Verify indicator displays correct status when
locked and unlocked.
Correct
Incorrect
Lock Screw
Outside
Front
#8-32
x 1/4"
Screws
Lock Screw