background image

P/N YRD256-MNL-0003 Rev G

18

    Setting Definitions

*The Master Entry Code must be created prior to any other programming of the lock.

Creation

required*

Inside Indicator Light

Disabled (Off)

Master Entry Code

Auto Re-lock

Disabled

Privacy Button

Disabled

The Master Entry Code is used for programming 
and feature settings. It must be created prior to 
programming the lock. The Master Entry Code will also 
operate (unlock/lock) the lock.

After a successful code entry or manual unlock 
with the key, the lock will automatically re-lock after 
each unlock in an effort to keep your home secure. 
This feature is optional, and can be turned off. 
When enabled, the lock will automatically re-lock 
after thirty (30) seconds.

Located on the inside lock. Shows active status 
(Locked) of lock and can be enabled or disabled in 
Advanced Lock Settings (Main Menu selection #3).

Privacy mode is disabled by default. When enabled, 
activate Privacy mode by pressing the privacy button for 
4 seconds to put the lock in do-not-disturb mode (all 
Entry Codes are disabled).

Wrong Code

Entry Limit

5 Times

After five (5) unsuccessful attempts at entering a 
valid Entry Code, the lock will shut down and not 
allow operation for sixty (60) seconds. 

Settings

Default Setting

Definition

One Touch Locking

Enabled

When the latch is retracted, activating the keypad 
will extend the latch (during Auto Re-lock duration 
or when Auto Re-lock is disabled). When One-Touch 
Re-lock is not in use (disabled), any valid Entry Code 
will re-lock the lock.

Volume

Enabled (Low)

The volume setting for Entry Code verification is set 
to Low (2) by default; otherwise it can be set to 
High (1) or Silent (3) for quiet areas.

Language

English

Choosing English (1), Spanish (2) or French (3) 
becomes the (default) setting for the lock voice 
prompts.

All Code Lockout

Disabled

This feature is enabled by the Master Entry Code. 
When enabled, it restricts all Entry Code access
(except Master). When attempting to enter a 
code while the lock is in All Code Lockout, the RED 
locked padlock will appear on the screen.

Shutdown Time

60 Seconds

The lock will shutdown (flashing RED) for sixty 
(60) seconds and not allow operation after the 
wrong code entry limit (5 attempts) has been met. 

Summary of Contents for Yale Assure Lock SL

Page 1: ...smart home system or Yale Acess app if purchased with Yale Smart Module or Yale Access Upgrade Kit Failure to follow these instructions could result in damage to the product voiding the factory warranty and could lead to failure of the product to provide access Before you begin Using the app on your smart phone scan this QR for step by step installation instructions to register your lock DOWNLOAD ...

Page 2: ...OR Screw Set D Silver for 2 to 2 1 4 Door Thickness Screw Set C Black Standard for 1 3 4 Door Thickness Strike Plate and Deadbolt Screws Inside Lock Screws Optional Security Strike Plate Screws Let s Get Started Screw Set B Green for 1 3 8 Door Thickness Yale Smart Module with select models What s In The Box Loosen screw to remove cover 4 AA Batteries Battery Cover Inside Lock Mounting Plate x2 x2...

Page 3: ...P N YRD256 MNL 0003 Rev G 3 Frame Remove Existing Deadbolt Do not discard old lock hardware until Assure Lock has been successfully installed 1 ...

Page 4: ...ify your door measurements and make any needed adjustments With door checker use template from installation guide envelope to prep a new door that has not been predrilled for hardware Check Your Door Guide New Door Marking Template 2 Check Door Measurements And Make Adjustments If Needed Let s Get Started Let s Get Started ...

Page 5: ...or purchase optional optional 2 3 8 Backset default 2 3 4 Backset optional Press Pull Bolt must be in retracted unlocked position Note horizontal orientation of tailpiece slot and UP orientation of deadbolt latch Backset For Strike Plate Actual Size x2 Choose standard strike plate screws or security screws For Strike Plate optional Actual Size Bolt must be in retracted unlocked position x2 3 Insta...

Page 6: ...Door Bolt must be in retracted unlocked position Note horizontal orientation of tailpiece slot 4 Install Touchscreen Keypad Door face hole must be at least 2 1 8 If hole is too small a door lock installation kit or jig should be used to increase hole size ...

Page 7: ...et D Silver for 2 to 2 1 4 Door Thickness x2 Screw Set C Black Standard for 1 3 4 Door Thickness Actual Size Actual Size Insert cable through cable hole Choose through bolt appropriate for your door thickness Verify appropriate through bolt with the door checker Screw Set B Green for 1 3 8 Door Thickness x2 5 Install Inside Mounting Plate ...

Page 8: ...Inside of Door Use cable hooks for proper cable routing Do not pinch cable 6 Attach Cable This Side Up mark Make sure cable is securely attached P N YRD256 MNL 0003 Rev G 8 ...

Page 9: ...P N YRD256 MNL 0003 Rev G 9 x3 Actual Size Inside of Door Make sure thumbturn is vertical If the thumbturn does not move freely refer to Hardware Troubleshooting Horizontal 7 Install Inside Lock ...

Page 10: ...P N YRD256 MNL 0003 Rev G 10 Inside of Door If thumbturn operation fails check the installation beginning with Step 3 Test Mechanical Operation ...

Page 11: ... be installed prior to inserting and or removing the Yale Smart module Inside of Door For more information about Yale Smart modules and smart home features visit US YaleHome com Smart O optional Install Yale Smart Module Included with select models ...

Page 12: ...e your lock Inside of Door Tighten screw to replace cover Welcome to Yale Real Living Bolt must be in retracted unlocked position before installing batteries Press the Yale logo to wake the lock You will be guided through setup by audio instructions on the lock Additional Entry Codes and further programming can be done through the Settings Menu Install Batteries and Cover 8 ...

Page 13: ...ery to the terminals in case of dead lock batteries Touchscreen Keypad Press to wake keypad or lock door Enter Master Entry Code and press to access Settings Menu Press to enter or unlock Using Your Lock Inside Lock Thumbturn for manual locking and unlocking Privacy Button Battery Cover Inside Notification Light P N YRD256 MNL 0003 Rev G ...

Page 14: ...e is to set your Master Entry Code with 6 or more digits and create a separate code that is used daily to lock and unlock the door Press Press Creating Master Entry Code Registered Enter a 4 to 8 digit PIN code followed by the gear key Register Master Code Press the gear key to continue 14 P N YRD256 MNL 0003 Rev G ...

Page 15: ...250 with Smart Module 25 without Press code flashes Creating Entry Codes Enter Master Entry Code Press Press Adding more Entry Codes Enter 4 8 digit Entry Code Press To end programming Press Menu mode press the gear key to continue Enter 4 8 digit Entry Code P N YRD256 MNL 0003 Rev G ...

Page 16: ...ress To delete all Entry Codes Does not delete Master Entry Code Press Enter To delete one Entry Code you must enter the Entry Code you wish to delete Enter Master Entry Code Menu Mode enter number press the gear key to continue Press Deleting Entry Codes P N YRD256 MNL 0003 Rev G ...

Page 17: ...P N YRD256 MNL 0003 Rev G 17 Enter Entry Code Press Unlocking Door with Entry Codes ...

Page 18: ...ot disturb mode all Entry Codes are disabled Wrong Code Entry Limit 5 Times After five 5 unsuccessful attempts at entering a valid Entry Code the lock will shut down and not allow operation for sixty 60 seconds Settings Default Setting Definition One Touch Locking Enabled When the latch is retracted activating the keypad will extend the latch during Auto Re lock duration or when Auto Re lock is disa...

Page 19: ... Enable Disable Enable 60 sec 3 min 2 min Disable 1 Press Yale logo to wake up lock 2 Enter Master Entry Code followed by icon Lock Response Welcome to the Settings Menu Press each number to hear available settings and then press the settings icon to enter 3 Enter digit corresponding to the function to be performed followed by the icon Follow the voice commands The Master Entry Code must be create...

Page 20: ...o see if Auto Re lock is enabled Disable Auto Re lock to lock the door manually If low battery indicator is lit change batteries Entry Codes must consist of 4 to 8 digits The same Entry Code cannot be used for multiple users Entry Codes are set by the Master Entry Code which is set first Contact the Master user Entry Codes must be entered within 5 seconds while keypad is active or process will have...

Page 21: ...crewdriver Using an electric driver may strip screw heads or enlarge screw holes 2 Locate strike plate tab Bend the tab towards surface of strike Note A small change may be all that is required 3 Reinstall strike plate using a manual screw driver and test again 4 If door cannot be adjusted sufficiently with strike tab both knob lever handleset latch and deadbolt latch could require adjustment we su...

Page 22: ... that to which the receiver is connected Ÿ Consult the dealer or an experienced radio TV technician for help Warning Changes or modifications to this device not expressly approved by Yale Home could void the user s authority to operate the equipment Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareillage numér...

Reviews: