6. Route all lockbody harnesses thru the mortise pocket and thru hole “E”.
7. Loosely fasten lockbody to door using combination screws.
8. Install the bottom post of O/S long escutcheon thru hole “D” and attach the
cylinder to the lockbody thru hole “B”.
9. Install the I/S short escutcheon by loosely fastening the #10-24 X 2 screws
thru hole “D” and to the post of the O/S long escutcheon.
10. Install the spindle assembly thru the lock.
Loosen the set screw on the inside
lever and remove inside lever before installing thru lock.
Be sure that the
lever on the pinned end of the assembly goes on the outside of the door and the
ramp of the inside spindle goes towards the set screw on the inside lever.
11. Install the inside lever and securely tighten the set screw.
12. Install harness connectors to the controller board (See Wiring Diagram on page 12).
For deadbolt monitoring connection see picture above.
13. Skip to page 11.
˝
Cylinder Applications
8851FL & 8853FL
Keypad
connector
Lockbody
motor
See picture for
to circuit board
connecting
Deadbolt
monitoring
IV-D Installing lockbody, short escutcheon and levers
8
9
10
7
6
REMOVE
BEFORE
USE
REMOVE
BEFORE
USE
Connect to
deadbolt monitoring
connector from lock
Grounding Strip