background image

 

 

 

Yale Locks 

Z-Wave+ System Integrators Guide 

Yale nexTouch Sectional Mortise Keypad Lock 

NTM 610/615/620/625/630/635/640/645  

 

 

 

 

 

Summary of Contents for Yale nexTouch NTM 610

Page 1: ...1 Yale Locks Z Wave System Integrators Guide Yale nexTouch Sectional Mortise Keypad Lock NTM 610 615 620 625 630 635 640 645 ...

Page 2: ...2 Contents Yale Z Wave Info 3 Supported Command Classes 3 Association Table 4 Notifications Table 4 Configurable Parameters 7 ...

Page 3: ...ave Info Command Class Manufacturer Specific Command Class Security Command Class Device Reset Locally Command Class Power Level Command Class Version Command Class Battery Command Class Door Lock Command Class Door Lock Logging Command Class Schedule Entry Lock Command Class User Code Command Class Time Parameters Command Class Time Command Class Association Command Class Association Group Info C...

Page 4: ...xFB Master code was changed over RF 0x06 0x0E User added 0x 01 max users User added Alarm level user slot number 0x06 0X0E User deleted 0x21 0x 01 max users User was deleted Alarm level user slot number 0x06 0X0D 0X0C Tamper Alarm 0xA1 0x01 keypad attempts exceed code entry limit 0x06 0X10 0x02 front escutcheon removed from main 0x06 0xFE RF Operate Unlock 0x19 0x01 by RF module 0x06 0X04 Keypad U...

Page 5: ...max users Where Alarm level represents user slot number Alarm generated in response to add user RF cmd This alarm is not generated when attempting to add duplicate pin at the keypad The lock simply denies it and plays the Denied Trying to duplicate the master code will result in a 0x71 0x00 alarm report 0x06 0x0F RF Module Power Cycled 0x82 0x00 Power to RFM was restored sent by RF module The lock...

Page 6: ...Day Schedule Enabled Disabled 0x63 0x 01 max users Schedule s has been enabled disabled for specified user ID 0x06 0xFE All Schedule Types Erased 0x64 0x 01 max users Schedule s has been set erased for specified user ID 0x06 0xFE All Schedule Types Enabled Disabled 0x65 0x 01 max users Schedule s has been enable disabled for specified user ID 0x06 0xFE Deadbolt Secured Unsecured 0x2A 0x0000 Deadbo...

Page 7: ...mode this is the default mode 01 vacation mode keypad lockout 02 privacy mode no keypad RF Unlock will work 03 passage mode Lock is permanently unlocked One Touch Locking 11 1 byte 0x00 OFF 0xFF ON default is 0xFF or ON Privacy Button 12 1 byte 0x00 OFF 0xFF ON default is 0x00 or OFF Lock Status LED 13 1 byte 0x00 OFF 0xFF ON default is 0xFF or ON Reset To Factory Defaults 15 1 byte 01 Lock will e...

Page 8: ...is 0x00 or OFF If supported switches lock to lower power mode of operation with reduced sound and led brightness Privacy Mode with Deadbolt 22 1 byte 0x00 OFF 0xFF ON default is 0x00 or OFF If enabled then extending the deadbolt will put the lock into Privacy Mode Lock Body Alarms Mask 23 1 byte Each bit controls one alarm 1 alarm enabled 0 alarm disabled 0xFF All Alarms on Default is 0xFF Bit 0 D...