background image

P/N YRD136-MNL-0008 Rev C

16

Definitions

All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code 
access. When attempting to enter a code while the unit is in Lockout, the lock rapidly beeps 5 times.

Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone play-back for use in quiet areas. Audio 
mode is enabled or disabled through feature programming by the Master code.

Automatic Re-lock Time: After a successful code entry or manual unlock with the key, the lock will automatically re-lock after 
each unlock in an effort to keep your home secure. This feature is optional, and can be turned off. In the ON mode, the lock will 
automatically re-lock after thirty (30) seconds.

Master PIN Code: The Master PIN code is used for programming and for feature settings. It must be created prior to 
programming the lock.
 The Master code will also operate (unlock/lock) the lock.

Network Setting: This setting is available through the wireless button on the interior escutcheon     and allows the lock to connect 
with a network controller.  

One Touch Locking: When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-lock duration or 
when Automatic Re-lock is disabled).

Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.

Shutdown Time: The unit will shutdown (flashing keypad) for sixty (60) seconds and not allow operation after the wrong code 
entry limit has been met. 

Low Battery: When battery power is low, the Low Battery Warning Indicator flashes RED. If battery power is completely lost, use 
the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals below the keypad for 
backup power option. Wake up the lock and enter your pin code to unlock the door. 

User PIN Code: The User code operates the lock. Maximum number of user codes is 250 in network.

Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, the unit will shut down and not allow 
operation for sixty (60) seconds. 

Summary of Contents for Yale Pro SL

Page 1: ...eadbolt with Z Wave Plus YRD136 Installation and Programming Instructions x4 x2 Silver x3 8 32 x 5 16 Machine screws 7 wood 8 32 machine x 20mm Combination screws M6x55mm PPHMS 2 1 4 OR x2 Black M6x44mm PPHMS Standard 1 3 4 2 OR x2 Gold M6x36mm PPHMS 1 3 8 Before you begin for step by step installation instructions to register your product DOWNLOAD THE BILT APP ...

Page 2: ...P N YRD136 MNL 0008 Rev C 2 Preparing Door and Keypad Escutcheon Cup must be removed from escutcheon if bore hole is less than 2 1 8 2 1 8 Application 2 1 8 Application ...

Page 3: ...RD136 MNL 0008 Rev C 3 x4 1 Installing Latch Strike Plate Rotate 2 3 8 position 2 3 4 position O optional Bolt must be in retracted unlocked position UP arrow must be facing upwards default 3 2 8 3 2 8 3 2 4 ...

Page 4: ... N YRD136 MNL 0008 Rev C 4 2 Installing Keypad Escutcheon Outside of Door Ensure cable is routed under the deadbolt If bore hole is less than 2 1 8 remove cup by gently compressing two tabs while pulling ...

Page 5: ...P N YRD136 MNL 0008 Rev C 5 x2 3 Installing Interior Mounting Plate Choose proper bolt length and color using guide on page 1 ...

Page 6: ...6 4 Attaching the Cable Assembly Avoid interference with movement of lock by routing cable as shown P N YRD136 MNL 0008 Rev C ...

Page 7: ...P N YRD136 MNL 0008 Rev C 7 x3 5 Installing Interior Escutcheon Thumbturn should be in vertical position ...

Page 8: ...P N YRD136 MNL 0008 Rev C 8 Testing Operation Deadbolt should extend and retract smoothly If not go back to step 2 Bolt must be in retracted unlocked position before installing AA batteries ...

Page 9: ...to wake lock Press Press Enter a 4 8 digit Master PIN code Press to complete Initial Programming Lock will not operate until gear is pressed and Master PIN code is set After entering the Master PIN code press any key to complete handing ...

Page 10: ...YRD136 MNL 0008 Rev C 10 6 Installing Cover Congratulations you ve installed the Yale Pro SL Key Free Keypad Deadbolt with Z Wave Plus YRD136 Continue with Programming Instructions to customize your product ...

Page 11: ...rk Warning Changes or modifications to this device not expressly approved by ASSA ABLOY Residential Group could void the user s authority to operate the equipment Low Battery Warning Flashes RED All Code Lockout Mode Rapidly beeps 5 times Failsafe 9 Volt Battery Connection Use Alkaline battery P N YRD136 MNL 0008 Rev C ...

Page 12: ...12 Changing Master PIN Code 1 Press Press Enter 4 8 digit Master PIN Code Enter Master PIN code Press Press Press P N YRD136 MNL 0008 Rev C ...

Page 13: ...ting User PIN Codes 2 Press Enter 4 8 digit PIN code Press Press Press Press Press Master PIN code must be created first Max User Codes 250 in network Enter Master PIN code Press P N YRD136 MNL 0008 Rev C 13 ...

Page 14: ...P N YRD136 MNL 0008 Rev C 14 3 Unlocking Door with PIN Code Press Unlock Enter PIN Press PIN Code Management Up to 250 Users in network Duplicate if necessary User Name PIN Code Code Chart ...

Page 15: ...of the lock Enrolling Lock In Z Wave Plus Network Your network controller first needs to be in enrollment or exclusion mode for the lock to be enrolled or removed from network Once you put the controller in the enrollment or exclusion mode the lock can be enrolled or removed in the Z Wave Plus Plus network by pressing the button To enroll lock using the button option 1 Remove the battery cover 2 Pr...

Page 16: ...he lock Network Setting This setting is available through the wireless button on the interior escutcheon and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled Tamper Alert Audible alarm sounds if attempting to forcibly remove outside l...

Page 17: ... Code Entry Limit 5 Times Shutdown Time 60 Seconds The Master PIN code must be registered prior to any other programming of the lock Default settings in bold M U Master PIN Code Setting User PIN Code Registration Register Delete Complete Handing the Lock Preforms automatic handing of the lock Advanced Lock Settings Automatic Re lock Disable 30 sec One Touch Locking Enable Disable Continue 60 sec 3...

Page 18: ...P N YRD136 MNL 0008 Rev C 18 Programming Troubleshooting Symptom Suggested Action Press each keypad key for response when pressed keypad flashes three times nd the ...

Page 19: ...d 2 this device must accept any interference including interference that may cause undesired operation of the device Model YRD136 ZW 619 605 0BP This radio transmitter 6982A YRHCPZW0FM has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated Antenna types not included in this list having a gain greater than the maximum gain ind...

Page 20: ...oses only Copyright 2020 All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Residential Group is prohibited NOTE TO INSTALLER AND CONSUMER While Yale has included several features to prevent lockout 9 Volt battery jumper low battery warnings it is still possible for a lockout situation to occur Because this product does not have a mechanical o...