13
An ASSA ABLOY Group brand
P/N AYRD220-INST-FUL Rev B
To return the lock to programming defaults:
1. Disassemble the lock using pages 6 and 7.
2. The reset button (see arrow) is located above the PCB cable
connector.
3. Hold down the reset button while reinstalling the batteries*.
4. Reassemble the lock using pages 6 and 7.
All programming should now be returned to factory defaults.
Return Lock to Programming Defaults
Cycle the lock in both the locked and the unlocked positions. If problems are found:
TROUBLESHOOTING
Symptom
Suggested Action
Door is binding
a. Check that door and frame are properly aligned and door is free swinging.
b. Check hinges: They should not be loose or have excessive wear on knuckles.
Bolt will not deadlock
a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing
the depth of the pocket for the bolt.
b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly
entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the
strike alignment.
Bolt does not extend or retract smoothly
a. Bolt and strike are misaligned, see above.
b. Check the backset of door relative to adjustments already made to bolt.
c. Verify proper door preparation and re-bore holes that are too small or misaligned.
Hardware Troubleshooting
MISCELLANEOUS
Return Lock to Programming Defaults ...................................................................13
Hardware Troubleshooting ......................................................................................13
Programming Troubleshooting ...............................................................................14
Replace/Install Cylinder .........................................................................................15
Sample Pin Code Management Sheets ........................................................... 16-17
Cable
*This procedure also clears the automatic handing for the
Yale Real Living™ locks (see item 9, page 7).
Reset Button