background image

8

OPERATING THE 

PRESSURE WASHER

POWER CLEAN GO 1100SS OWNER’S MANUAL

USER OPERATED CONTROLS

OFF/ON Switch

:  The power OFF/ON Switch is used to turn 

the pump motor on and off as necessary for operation.  The 
OFF/ON Switch is located on side of the machine.  

Spray Gun

:  The spray gun assembly provides the 

operator control of the flow, pressure, and pattern of the 
high-pressure spray.  Squeezing the gun trigger while 
directing the spray nozzle toward the surface to be 
cleaned operates the spray gun.  Your spray gun may be 
equipped with a dual nozzle or vari-nozzle. 

 

»

Dual Nozzle: 

 The dual nozzle selector is used to select 

either the low-pressure “soap” nozzle or the high 
pressure “rinse” nozzle.  Selection of the desired nozzle 
must be made while the spray gun trigger is released.  
To select the low-pressure nozzle, rotate the spray gun 
90˚ counterclockwise so that the spray gun handle 
is parallel to the ground with the hose connection 
extending to the operators right, then squeeze the 
trigger.  To select the high-pressure nozzle, rotate the 
spray gun 90˚ clockwise so that the spray gun handle 
is parallel to the ground with the hose extending to 
the operator’s left, then squeeze the spray gun trigger.  
Once the nozzle has been selected and the spray gun 
trigger held open, the spray gun may be rotated and 
aimed at the surface.

 

»

Vari-Nozzle:

  The vari-nozzle is used to select either 

low-pressure “soap” or high-pressure “rinse”, and to 
adjust the spray-pattern from a wide-angle spray to 
a zero-degree stream.  For high-pressure, pull the 
nozzle-body firmly toward the spray-gun handle.  To 
select low-pressure, push the black nozzle body firmly 
away from the spray gun handle.  To vary the spray 
pattern of the nozzle, twist the black nozzle body 
clock ways to narrow pattern and counter clock ways 
to widen the spray pattern.

Chemical Metering Knob:

 The chemical metering knob is 

located at the front end of the spray washer on top of the 
chemical injector where the chemical pick up occurs.  The 
chemical pickup line feeds into one end of the metering 
knob. It is a black in color.  Please refer to the Chemical 
Dilution Chart at back of this Owner’s Manual. 

PRE-OPERATION CHECK

 

»

Perform the pre-operation daily maintenance check 
prior to operating the unit to ensure safe operation 
and prolonged equipment life.

 

»

Read safety, operation, and maintenance instructions 
before starting machine.

DAILY MAINTENANCE

 

»

Check oil level.  Fill to center of sight glass.  See “Oil” in 
General Maintenance Section.

 

»

Check to see that the GFCI power cord is in good 
condition.  Replace complete GFC cord assembly if 
either the GFCI, plug or cord is damaged, frayed or 
worn.  Test the GFCI circuit weekly by pressing the 
TEST button on the GFCI.  Reset the GFCI after test by 
pressing the RESET button on the GFCI.

 

»

Hoses

 – Check hoses for breaks and damaged fittings.  

Replace as needed.

 

»

Spray Gun 

– Check spray gun for damaged fittings, 

nozzle, and trigger.  Replace as needed.

PREPARATION FOR USE

 

»

Verify that the surface or equipment to be cleaned can 
withstand the high-pressure spray.

 

»

Wear safety googles or other approved eye protection 
when cleaning with high-pressure spray washers.

 

»

Check with your Safety Representative for other 
Personnel Protective Equipment (PPE) that may be 
required for the job being performed.

 

»

Clear area of slip or trip hazards.  Keep area clear while 
cleaning.

 

»

Ensure the OFF/ON switch is set to the “OFF” position.  

 

»

Attach high-pressure hose to discharge nipple with 
quick coupler. Lock quick coupler in place by pulling 

Summary of Contents for SprayMaster POWER CLEAN GO 1100SS

Page 1: ...POWER CLEAN GO 1100SS OWNER S MANUAL IMPORTANTDOCUMENT DONOTDISCARD FOR COMMERCIAL USE ONLY www spraymastertech com A brand line of MANUFACTURED DATE SHIPPED SERIAL NUMBER ...

Page 2: ...casters and handles check valves and chemical injectors The following items are covered by the above warranty for 1 year from the date of shipment Unloaders Chemical Valves Electrical Components float switch temperature switch Solid State Relay Master Control Panel electronic injectors wiring harnesses and flow switch LABOR AND TRAVEL Labor and travel to repair or replace defective parts shall be ...

Page 3: ...NCE General Maintenance Moving Storage CHEMICAL METERING Chemical Metering Instructions Manufacturer s Recommended Dilution Chart OWNER USER RESPONSIBILITY The owner and or user must understand the operating instructions and warnings before using this pressure washer Warning information should be emphasized and understood Owner and operator must study this manual and keep handy for future referenc...

Page 4: ...ESSURE WASHER UTILITY REQUIREMENTS WATER Flow Rate Minimum 5 GPM Pressure 30 PSI min to 80 PSI max Temperature 150 F max 65 5 C ELECTRICAL Power Clean Go 1100SS 120V 60Hz 20AMP RETURNING YOUR PRESSURE WASHER Any item returned for warranty or for credit must have a Returned Authorization Number Call our Customer Service Department to discuss your return request Please note that all items returned m...

Page 5: ... of the machine and result in death serious bodily injury and or property damage 1 Read these instructions before using the product 2 To reduce the risk of injury close supervision is necessary when a product is used near children 3 Know how to stop the machine and bleed pressure quickly Be thoroughly familiar with the controls 4 Stay alert Watch what you are doing 5 Do not operate the product whe...

Page 6: ...utes Keep operating area clear of all persons RISK OF INJECTION OR SEVERE INJURY TO PERSONS KEEP CLEAR OF NOZZLE To reduce the risk of injury close supervision is necessary when a machine is used near children Do not allow children to operate the pressure washer This machine must be attended during operation Never make adjustments on machine while in operation Be certain all quick coupler fittings...

Page 7: ...ed frayed or worn EXTENSION CORDS Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole cord connectors that accept the plug from the products Use only extension cords that are intended for outdoor use These extension cords are identified by a marking Acceptable for use with outdoor appliances store indoors while not in use Use only extension cords having an electrical ...

Page 8: ...e spray gun handle To vary the spray pattern of the nozzle twist the black nozzle body clock ways to narrow pattern and counter clock ways to widen the spray pattern Chemical Metering Knob The chemical metering knob is located at the front end of the spray washer on top of the chemical injector where the chemical pick up occurs The chemical pickup line feeds into one end of the metering knob It is...

Page 9: ...ng to the instructions for the chemical you are using Use high pressure spray to rinse the surface or equipment being cleaned Rinse thoroughly Upon completion of the cleaning job flush the chemical from the chemical injector by removing the chemical feed line and place into a clean container of water Operate the spray gun on low pressure for one minute Turn the OFF ON switch to OFF Squeeze the spr...

Page 10: ...ife longevity Do not operate your pump without a water supply filter Replace with 5 micron water supply filter every 3 months or as needed to ensure an adequate supply of clean water to the pump A dirty water filter can restrict water flow and cause intermittent shutdown of the pump Chemical Foot Screen Flush the chemical foot screens and injector with warm water to remove chemical buildup that ca...

Page 11: ...ounces per gallon will need to inject 5 ounces of chemical over a 36 second period Fill a measuring cup graduated in ounces with the chemical to be injected and submerge the chemical pick up tube with the foot screen into the chemical Turn the pump ON and set it to inject chemical Adjust the chemical metering device so that 5 ounces of chemical is injected in the duration of time identified in Ste...

Page 12: ... 2020 Assembled Products Corp Inc 200519_SMT_1100SS_PCG OM_EN Rev 00 115 Linden St Rogers AR 72756 USA 800 548 3373 A brand line of ...

Reviews: