3
d. Once the unit has a Gd.9 status, charge the unit another three
to six hours, (three hours is acceptable but to ensure maximum
output capability, six hours is preferred).
e
. If you are not going to need the KS400/KS401 right away you
may leave the KS400/KS401’S internal charger connected to
the AC power source. We recommend that the KS400/KS401’s
internal charger remain connected to an AC power source
whenever the KS400/KS401 is not in use.
2.
USING THE DC POWER EXTENSION CORD.
Plug one end of
the DC power extension cord into the KS400/KS401’s power
receptacle and the other end into a vehicle’s lighter outlet (the
vehicle’s engine should be running first). Push the test button
once every hour
to check the unit status by pushing the “Status
Button” DO NOT OVERCHARGE! This is not an automatic
method of charging the KS400/KS401. You must frequently
monitor the charging process to ensure the KS400/KS401 is not
overcharged. Overcharging will damage your KS400/KS401.
Note: Status button needs to be pressed to check power level.
OPERATING INSTRUCTIONS
USED AS A BATTERY CHARGER
The KS400/KS401 is intended, primarily, to be used to start or
restart a vehicle when the battery in the vehicle has become run
down to the point that it will not start the vehicle without assistance.
However, the KS400/KS401 can also be used to restore some
charge to the vehicle battery.
1. Plug the DC power extension cord from the KS400/KS401 into the
vehicle’s cigar lighter outlet for 30 minutes.
NOTE: Some vehicle’s ignition keys must be turned to accessory to
activate the cigar lighter socket.
2. Remove the DC power extension cord and start the car.
NOTE: A defective battery may refuse to accept a charge from the
KS400/KS401.
USED AS AN EMERGENCY JUMP STARTER
NOTE: For optimum performance, do not store below 50°F when
using as a jump starter.
1.
Turn ignition off before making cable connections.
2.
Use in a well-ventilated area.
3. SHIELD
EYES.
4.
Clamp the positive (red +) clamp to the positive terminal on the
weak battery (for negative ground system).
5.
Clamp the negative (black –) clamp to the vehicle frame
(ground). Make sure the cables are not in the path of moving
belts or fan.
NOTES:
a.
If cables are attached in reverse, 888
→
REV will flash on
the display.
b.
When the cables are connected and the unit switch is in
the OFF position the display will flash
“888
→
SW
→
ON
→
Vdc” (vehicle battery voltage is
displayed).
6.
Turn unit switch to the “ON” position. Display will flash
“888
→
SW
→
ON
→
Vdc”.
7.
Stay clear of batteries while jump starting.
8.
Start the vehicle (turn on the vehicle ignition).
NOTE: If the vehicle does not start within 6 seconds, let the
KS400/KS401 internal battery cool for 3 minutes before
attempting to start the vehicle again or damage to the
KS400/KS401 may occur.
9.
When the vehicle is started, turn unit switch to “OFF” position,
disconnect the negative (–) battery clamp from the vehicle
frame.
10. Disconnect the positive (+) clamp.
USED AS AN ALTERNATIVE POWER SUPPLY
FOR VEHICLES
The KS400/KS401 is an essential tool for all who replace automobile
batteries. Most vehicles have some type of electronic component
with memory, such as alarm systems, computers, radios, phones,
etc… and when the vehicle’s battery is replaced, memory is lost.
However, if the cigar lighter power extension cord is plugged from
the KS400/KS401 into the vehicle’s cigar lighter socket, the
memories can be saved.
Note: Some vehicles may require the KS400/KS401 to be connected
to the vehicle’s OBD2 connector to save all memory functions. The
MS6209
memory saver may be purchased separately for these
applications.
MULTI PURPOSE POWER SUPPLY
The KS400/KS401 is also a portable power supply for all 12 VDC
accessories equipped with a male cigar lighter plug or USB
connector. The DC outlet and USB port have automatic overload
protection.
To use the USB port, press and hold the Status button for 5
seconds, the display will flash “USB”. To turn off the USB press and
hold the Status button for another 5 seconds, the display will flash
“USB OFF”.
Note: To prevent battery voltage drop ALWAYS turn off the
USB port.
For maximum battery life do not discharge below 11V.
When the KS400/KS401 is used with an inverter, it can operate
appliances normally powered by 120 VAC or 220 VAC in Europe.
Recommended inverter for the KS400/KS401 is 300 watts
maximum. For more information contact your nearest KS400/KS401
dealer.
!!! IMPORTANT !!!
BATTERY REMOVAL AND DISPOSAL
Contains sealed, non-spillable lead
acid battery. Must be disposed of
properly.
The battery inside this KS400/KS401 is a sealed lead-acid battery.
By LAW,
it is required to be removed and recycled or disposed of
properly
.
While there are regulations that must be followed
throughout your country, your local governments may have
additional regulations to be followed in your area.
When the battery in this product is in need of replacement, remove it
according to the instructions provided below and take it to your local
recycling center for proper recycling or disposal. If you don’t have a
local recycling center that handles sealed lead-acid batteries,
contact your local environmental agency for instructions.
BATTERY REMOVAL INSTRUCTIONS
Begin by making sure the unit’s power switch is in the “OFF”
position. You will need a T20 Torx head screwdriver and a 3/8”
socket.