Examples
:
I.)
Desired: Fullscale
100kg
Resolution 0.01kg
Menu
-
Stability settings are done according to operators environment.
-
set
“MU”
to
“kg”
3.1.1.2
-
“Dn” = 100kg / 0.01kg = 10000
set “Dn” to 10000
Æ
A810 is legal-for-trade
3.1.2.1.1
-
set
“VS”
=
0.01
3.1.2.1.2
-
for confirmation of correctly set parameters: “FS” shows 100.01kg
3.1.2.1.3
II.)
Desired: Fullscale
30t
Resolution 0.002t
Menu
-
Stability settings are done according to operators environment.
-
set
“MU”
to
“t”
3.1.1.2
-
“Dn” = 30t / 0.002t = 15000
set “Dn” to 15000
Æ
A810 is not legal-for-trade
3.1.2.1.1
-
set
“VS”
=
0.002
3.1.2.1.2
-
for confirmation of correctly set parameters: “FS” shows 30.002t
3.1.2.1.3