Feed Conveyor
•
Direction arrows indicate the direction that the feed
chain is moving.
•
Actual Feed Speed indicates the actual live speed.
The adaptive control system controls the feed sys-
tem by varying the actual feed speed, depending on
how far the engine speed is from the no-load set
point.
•
Set Feed Speed indicates the feed speed setting
(changed at the control panel and on the Machine
Home Page).
•
Feed Conveyor: the conveyor speed is displayed as
RPM and seconds per revolution.
•
Pressure indicates the hydraulic pressure required
to move the feed chain.
•
Engine RPM bar graph and the numerical readout
below the bar graph indicate the engine speed.
The engine speed may decrease until the next set
point is reached. When the engine speed drops
below the reverse point, the feed system reverses. If
the engine speed is above the no-load set point, the
feed speed system operates at full speed.
Engine speed setpoints can be adjusted for the fol-
lowing feed system actions:
•
Feed Full (full speed forward): press
A
to set.
•
Feed Adaptive (feed stop): press
B
to set.
•
Feed Stop (Reverse Below Stop): Press
C
to set.
•
Feed Reverse: Press
D
to set Low RPM Reverse
Time.
For a description of these parameters, see “Feed
System Setup” on page 142.
•
Engine Load indicates the engine load in percent.
•
Discharge Conveyor
displays the current status
of the discharge conveyor: Stopped, Slow, Medium,
or Fast (speeds).
Once the discharge conveyor is running, the speed
can be set with this control.