Feed Stop Setpoint:
the engine speed (rpm) at
which the feed system stops moving forward. The feed
system is adaptive between the Feed Full Forward Set-
point and the Feed Stop Point.
Reverse Below Stop Setpoint:
the engine speed,
in rpm, below the Feed Stop Point, where the feed sys-
tem reverses for the Low RPM Reverse Time.
Low RPM Rev Time:
the time, in ms (milliseconds),
that the feed system reverses after the engine falls below
the feed reverse point.
Feed Reverse Speed:
a comparable percentage of
the feed system at full speed forward.
Min Auto Down Pulse Height:
the required height
of the compression roll, in inches, for the automatic
down pressure feature to function. If the compression
roll is below this setpoint, the auto down pressure does
not apply.
F’Cnvr (Feed Conveyor) Over-Pressure:
pres-
sure setpoint, in psi, that the feed conveyor must reach
to trigger an over-pressure feed reverse.
C’Roll (Compression Roll) Over-Pressure:
pressure setpoint, in psi, that the compression roll must
reach to trigger an over-pressure feed reverse.
Feed Full Forward Eng Load:
when Feed System
Option 3 is selected, this parameter controls when the
feed system is at full forward speed. The parameter is
displayed as a percent of the engine load.
Example: if this parameter is set to 70%, then as the
engine load falls to 70% or lower, the feed system func-
tions at full forward speed.
Feed Stop Eng Load:
when Feed System Option 3
is selected, this parameter controls when the feed sys-
tem stops. The parameter is displayed as a percent of the
engine load.
Example: if this parameter is set to 90%, then as the
engine load rises to 90% or above, the feed system
stops.
Figure 124:
Feed System Information Page Adjustments
To adjust the C’Roll Ratio and Feed System Setup:
Use the “-” or “+” symbols to decrease or increase value.
Press the “
” to select or “X” to cancel.
Feed System Setup:
Feed Full (A)
Feed Adaptive (B)
Feed Stop (C)
Feed Reverse (D)
F10024
F10777
F10778
F10779
F10780
Summary of Contents for Peterson 6710D
Page 6: ...C O N T E N T S 4 67 1 0 D G R I N D E R O P E R A T O R SA F E T Y M A N U A L 109401B ...
Page 158: ...16 2 67 1 0 D G R I N D E R O P E R A T O R SA F E T Y M A N U A L 109401B ...
Page 166: ...I N D E X 17 0 67 1 0 D G R I N D E R O P E R A T O R SA F E T Y M A N U A L 109401B ...
Page 167: ......