background image

A41606-ENC, 60 6A  User Manual 

 

 

4

 

Copyright © 2011 by Astek Corporation.  All rights reserved 

90-000243-A 

APRIL 29, 2016 VERSION A 

This document describes Astek’s a41606-ENC, 60 6A design and will remain the official reference source 
for all revisions/releases of this product until rescinded by an update. 

To receive product literature, visit us at 

http://www.astekcorp.com

 
DISCLAIMER 

Astek Corporation reserves the right to make changes to any products herein at any time without notice.  
Astek does not assume any responsibility or liability arising out of the application or use of any product 
described herein, except as expressly agreed to in writing by Astek; nor does the purchase or use of a 
product from Astek convey a license under any patent rights, copyrights, trademark rights, or any other of 
the intellectual property rights of Astek or third parties.  Astek products are not intended for use in critical 
navigation, industrial control, nuclear power or life-support appliances, devices, or systems.  Use of any 
Astek product in such applications without written consent of the appropriate Astek officer is prohibited. 

 

TECHNOLOGY LICENSES 

The hardware and/or software described in this document are furnished under a license and may be used 
or copied only in accordance with the terms of such license. 

 

REGULATORY COMPLIANCE 
Notice: FCC and CE testing is pending. This board is for ENGINEERING USE ONLY. 

Note: The A34812-ITX has been designed to comply with the limits for a Class A digital device, pursuant to 
part 15 of the FCC Rules. These Limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in its installation. This equipment generates, uses, can radiate 
radio frequency energy, and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications. If this equipment does cause harmful interference the user 
will be required to correct the interference. 

The A41606-ENC 60 6A  has been designed to meet the safety requirements of IEC/EN 60950-1. 

 

COPYRIGHT NOTICE 

Copyright © 2016 by Astek Corporation.  All rights reserved. 

 

TRADEMARK ACKNOWLEDGMENT 

The Astek logo design is the trademark or registered trademark of Astek Corporation. 

 

Summary of Contents for A41606-ENC

Page 1: ...A41606 ENC D60 6A Dual Ported 16 Bay 6Gb s Storage Enclosure with Cryptographic Erase Functions Key Erase User s Manual April 25 2016 Version A ...

Page 2: ...A41606 ENC 60 6A User Manual 2 Copyright 2011 by Astek Corporation All rights reserved 90 000243 A ...

Page 3: ......

Page 4: ...uct in such applications without written consent of the appropriate Astek officer is prohibited TECHNOLOGY LICENSES The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license REGULATORY COMPLIANCE Notice FCC and CE testing is pending This board is for ENGINEERING USE ONLY Note The A34812 ITX has ...

Page 5: ......

Page 6: ...k Corporation All rights reserved 90 000243 A Table of Contents 1 Introduction 7 2 Hardware Installation 7 3 Cryptographic Erase 9 4 Electrical Specifications 10 5 Environmental Specifications 10 6 Mechanical Specifications 11 7 Use Cases 12 8 Support 14 ...

Page 7: ...r module combined with a precision machined chassis and a unique sled less disk mounting mechanism these enclosures can hold up to sixteen 2 5 hard disks The A41606 ENC provides two external SAS x4 wide port input output connections per expander with each wide port supporting up to 24Gbps of I O Each port can be connected either to a host or another A41606 ENC allowing system designers to cascade ...

Page 8: ...ration All rights reserved 90 000243 A Step 2 Connect SAS cables to back of chassis Step 3 Insert Hard Drives using four shoulder screws for each drive Primary Ports Secondary Ports CLI RS232 Serial Interface for Primary CLI RS232 Serial Interface for Secondary ...

Page 9: ...evel commands Start Sanitization santest Start the entire Sanitization process Disable Host Side Phys Perform Sanitize Key Erase on all drives Prints first 512B of LUN 0 from each drives Block Erase all drives in the systems Prints test results Sanitize LED gpioState On 0 OFF 1 BLINK 2 BLINK_FAST 3 Verify the Sanitization LED is operating properly Disable Host Phys SSpDisablePhy Disables the Host ...

Page 10: ...ion 40W w o drives Maximum Power Consumption 200W SAS SATA SAS SATA speeds 1 5Gb s 3 0Gb s 6 0Gb s Number of SAS SATA bays 16 Serial Port Connection Speed 115 200 Connection Parameter 8 N 1 5 Environmental Specifications Operating Conditions Temperature 15 C to 45 C Humidity 5 to 90 non condensing Storage Conditions Temperature 10 C to 85 C Humidity 5 to 90 non condensing Airflow Number of Fans 4 ...

Page 11: ... 6A enclosure provides four fans to cool the board and chassis elements By default all fan outputs will be configured for full speed operation at start CAUTION Do not operate the A41606 ENC 60 6A continuously without sufficient cooling The default configuration does NOT support auto shutdown due to exceeding thermal limits and as such damage many occur to your board is operated continuously withou...

Page 12: ...A41606 ENC 60 6A User Manual 12 Copyright 2011 by Astek Corporation All rights reserved 90 000243 A 7 Use Cases Single Host Single Host with Redundant Path ...

Page 13: ...90 000243 A Copyright 2011 by Astek Corporation All rights reserved 13 Dual Host for Shared Storage Dual Host with Redundant Path ...

Page 14: ... 6A User Manual 14 Copyright 2011 by Astek Corporation All rights reserved 90 000243 A 8 Support For additional support email support astekcorp com Astek can be contacted at 719 260 1625 or toll free at 800 850 9055 ...

Reviews: