background image

 

 

HSIT Connector Saver Board 
SAS2 

Users Guide

 

Version A 
March 27, 2012 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Quantum Parametrics is a trademark of Astek Corporation 
Web: www.astekcorp.com

 

HSIT Connector Saver SAS1 User’s Guide 

Doc. 90-000259 

 

Version A 3/27/12

 

©2012 Astek Corporation.  All rights reserved.

 

2

 

 

i.

 

Revision History 

Revision  ECO# 

Date 

Description 

C01074 

3/27/12  Initial Release 

 

 

 

 

 

ii.

 

Reference Documents 

Document # 

Title 

Author 

 

iii.

 

Approval 

Approver 

Title 

Approval Date 

Joshua Sneller 

Hardware Design Engineer 

3/27/12 

Summary of Contents for Quantum Parametrics SAS2

Page 1: ...orp com HSIT Connector Saver SAS1 User s Guide Doc 90 000259 Version A 3 27 12 2012 Astek Corporation All rights reserved 2 i Revision History Revision ECO Date Description A C01074 3 27 12 Initial Release ii Reference Documents Document Title Author iii Approval Approver Title Approval Date Joshua Sneller Hardware Design Engineer 3 27 12 ...

Page 2: ...er Circuit Board 8 6 Contacting Astek Corporation 9 HSIT Connector Saver SAS1 User s Guide Doc 90 000259 Version A 3 27 12 2012 Astek Corporation All rights reserved 4 1 Connections MiniSAS 4x to MiniSAS 4x x4 6Gbps 2 Lines Tested 2 1 High Speed Lines MiniSAS 4x MiniSAS 4x 8 Lanes TX0 3 both directions 6Gbps 2 2 TX RX Parameters The HSIT is configured to output a 600mV nominal CJT Pattern during t...

Page 3: ...ation All rights reserved 6 3 Faceplate Loaded Switch Connectors Figure 2 Faceplate front view Loaded Switch press the Loaded Switch after loading a MiniSAS 4x to MiniSAS 4x x4 cable to the device to begin testing Connectors this Connector Saver Module supports testing of MiniSAS 4x to MiniSAS 4x cables LEDS o Active indicates that the HSIT is powered and ready to be used or is in use o Testing bl...

Page 4: ...can cause damage to the Connector Saver or the HSIT device 3 Press firmly with both thumbs to cause the connector to click into place 4 Secure the faceplate using the captive screws on the Connector Saver Faceplate NOTE Ensure ESD safe practices when handling the Connector Saver device HSIT Connector Saver SAS1 User s Guide Doc 90 000259 Version A 3 27 12 2012 Astek Corporation All rights reserved...

Page 5: ... to the bracket with the name serial number and TLA number facing up and the golden connector contacts facing away from the faceplate 5 Replace the Module into the HSIT device 6 Contacting Astek Corporation Astek Corporation D B A Quantum Parametrics Astek may be contacted by phone at 719 260 1625 USA or by email at sales astekcorp com or visit our web site at http www astekcorp com test and measu...

Reviews: