8
Dimming
When the light is turned-on press the key-switch until the desired illumination is achieved. By another
pressing of the key-switch the luminosity will increase to the maximum illumination.
Set default
Press the key switch for min. 40 seconds or until the light is turned off.
Synchronization
When more than one multi-color underwater light is connected to the system the optional
Synchronization Unit MSU08 is recommended to synchronize the colors of lighting at the Rainbow /
Turqouise Color Spectrum mode of lighting. On the other case the colors of all installed lights would
not be the same after few minutes or hours of operation in the Rainbow / Turqouise Color Spectrum
mode.
If the multi-color light is used only with one of the fixed color of lighting the synchronization is not
necessary.
DMX512 control
The built-in ASTEL protocol enables the network connection to control the lights with the standard
DMX512 protocol by using optional MXU01 or MXU03 interfaces.