Aston Technologies Inc.
www.astontechusa.com
- 15 -
every rotation is more than
dozens of grams.
the tire.
2. Main board or power
panel goes wrong.
3. Sensor is placed
unsteadily.
4. Outer power voltage
is lower.
2. Replace it.
3.
Check
sensors
and
connecting line.
4. Examine and repair or install
the manostat.
Non-stopping time is more
than 10s.
1. Power supply is loose
contact.
2. Disturb.
1. Check outer power circuitry
or replace power supply.
2. Shut down and start again.
Balancing inaccurately and do
not up to 00
1. Sensor is affected with
damp.
2. Mainboard goes
wrong.
3. Program is
disordered.
1. Adjust again, drying it and
self-calibrate.
2. Replace mainboard.
3. Self-calibrate over again.
Display value but not brake.
1. Brake system is
damaged.
2. External disturbs.
1. Replace power panel.
2. Start over again.
Twice dismounting error is
more than 10g.
1. The inner hole of
wheel is not regular.
2. Adapter is installed
improperly.
1. Replace the wheel.
2. Check the assembly surface
over again.
Self-calibration displays Err8. 1. Power panel goes
wrong.
2. Lead wire of sensor
fall back.
1. Replace wheel and try again.
2. Connect it.
Display error value of several
hundred grams
1. Three memory
parameters is
disordered.
2. Tire error is much
greater.
3. Mainboard goes
wrong.
1. Input over again.
2. Replace a tire.
3. Replace mainboard.
6. Structure of pressure sensor and steps of adjustment
During the transportation or operation process, pressure sensors are affected
with damp, which results in balancing the tire inaccurately. Then drying
pressure sensors. Operate the machine after calibrating.
Summary of Contents for ADP-2000L
Page 1: ...Aston Technologies Inc www astontechusa com 1 Wheel Balancer User s Manual Model ADP 2000L...
Page 21: ...Aston Technologies Inc www astontechusa com 21...
Page 22: ...Aston Technologies Inc www astontechusa com 22...
Page 23: ...Aston Technologies Inc www astontechusa com 23...
Page 24: ...Aston Technologies Inc www astontechusa com 24...