Before starting cleaning works, make sure that:
• The electrical supply switch on the rear panel of the stove is OFF;
• All stove components and ashes have cooled down sufficiently;
• Suitable tools will be used for cleaning;
• The electrical cable is unplugged when flue channels are to be cleaned.
When cleaning the combustion chamber, be careful and do not clog the pressure sensor’s pipe which
is mounted inside, on the left wall of the chamber, under a vermiculite plate. The pipe must remain
unobstructed.
The frequency of maintenance and cleaning depends directly on the quality of pellets used. Burning high quality pellets allows you
to devote less time and attention to cleaning activities, and to increase the periods between cleanings. Vice versa, bad quality pellets
will require shorter intervals between cleaning tasks. The quality of the pellets and a sound adjustment of combustion are essential
to the reliable operation of the stove.
The pellet stove is a generator of heat and technically
sophisticated appliance. Therefore, we strongly recommend
servicing by qualified personnel at least once a year, at
the start of the heating season to ascertain and ensure
the continued function and efficiency of all the stove's
components.
• EXTERIOR SURFACES CLEANING
To clean the surfaces on the painted metal parts, use a cloth
slightly moistened in water. If necessary, mild soap may also
be used. Rub the surfaces gently and with care.
Do not use any aggressive detergents or
solvents – they can cause serious damage to
the surfaces of the stove. Do not scrub excessively the
metal paint - the structured paint surface changes its
shading because of rubbing impact.
• HEAT EXCHANGER TUBES CLEANING
The heat exchanger is composed of stainless steel tubes.
Smoke flows constantly around the outer surface of the
tubes leaving soot residues on them. These residues must be
removed every 2 days of operation. For this purpose, inside
the heat exchanger there is a scraper which brushes the
tubes' surfaces like a comb. Pull the handle of the scraper 1
( Fig. 12) towards yourself. To complete the cleaning session,
push and pull this handle till halting several times.
• ASHES DRAWER CLEANING
The ashes drawer must be cleaned daily or every 2 days,
depending on the length of time the stove is used and the quality
of pellets used. To access the ashes drawer, open the door, remove
the ashes drawer 4 (Fig. 12) and empty it.
•COMBUSTION CHAMBER CLEANING
Clean the combustion chamber every 2 days. Use a drum-type
vacuum cleaner for cleaning the combustion chamber. Make sure
that no ashes are left after the cleaning session.
Fig. 13
Clean fire pot. No residue
inside, all the holes clean and
visible.
Fig. 14
Pot with the holes
blocked by ashes. Cleaning
required.
Fig. 12
Frequently inspected elements and their locations.
1. Scraper; 2. Combustion chamber; 3. Fire pot; 4. Ashes drawer.