DRV-28 inverter
s Function parameter list
-136-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P02.07
Rotor resistance
of asynchronous
motor 1
0.001–65.535Ω
Depend
on model
○
P02.08
Leakage
inductance of
asynchronous
motor 1
0.1–6553.5Mh
Depend
on model
○
P02.09
Mutual
inductance of
asynchronous
motor 1
0.1–6553.5Mh
Depend
on model
○
P02.10
No-load current
of asynchronous
motor 1
0.1–6553.5A
Depend
on model
○
P02.11
Magnetic
saturation
coefficient 1 of
iron core of
asynchronous
motor 1
0.0–100.0%
80.0%
○
P02.12
Magnetic
saturation
coefficient 2 of
iron core of
asynchronous
motor 1
0.0–100.0%
68.0%
○
P02.13
Magnetic
saturation
coefficient 3 of
iron core of
asynchronous
motor 1
0.0–100.0%
57.0%
○
P02.14
Magnetic
saturation
coefficient 4 of
iron core of
asynchronous
motor 1
0.0–100.0%
40.0%
○