DRV-28 inverter
s Function parameter list
-215-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
1: Pulse mode
Bit7: Reference point calibration mode
0: Calibrate at the first time
1: Calibrate in real time
Bit8: Action selection after zeroing signal
cancellation (electric level type)
0: Switch to speed mode
1: Position lock mode
Bit9: Positioning completion signal selection
0: Electric level signal
1: Pulse signal
Bit10: Z pulse signal source
0: Motor
1: Spindle
Bit11–15: Reserved
P22.01
Speed of spindle
orientation
During spindle orientation, the speed of the position
point of orientation will be searched, and then it will
switch over to position control orientation.
Setting range: 0.00–100.00Hz
10.00Hz
○
P22.02
Deceleration time
of spindle
orientation
Deceleration time of spindle orientation.
Spindle orientation deceleration time means the time
needed for the inverter to decelerate from Max.
output frequency (P00.03) to 0Hz.
Setting range: 0.0–100.0s
3.0s
○
P22.03
Spindle zeroing
position 0
Users can select the zeroing positions of four
spindles by terminals (function code 46, 47).
Setting range: 0–39999
0
○
P22.04
Spindle zeroing
position 1
Setting range: 0–39999
0
○
P22.05
Spindle zeroing
position 2
Setting range: 0–39999
0
○
P22.06
Spindle zeroing
position 3
Setting range: 0–39999
0
○
P22.07
Spindle
scale-division
angle 1
Users can select seven spindle scale-division values
by terminals (function code 48, 49 and 50).
Setting range: 0.00–359.99
15.00
○
P22.08
Spindle
scale-division
angle 2
Setting range: 0.00–359.99
30.00
○