AS64 series AC servo drive Control modes
-44-
Signal of externally controlling quick stop.
If this digital input is valid, the control motor of the drive decelerates from current speed to 0
according to the regular curve set by P0.69 [DEC time for quick stop]. If it changes from valid to
invalid, the motor restores to the state prior to quick stop.
Signal
Symbol
Function
Applicable
mode
PTP control stop
PTP-ST
0x1E
P
Signal of controlling whether to stop PTP running in PTP mode, valid in the rising edge. In bus
control mode, if P5.20 [PTP trigger signal] is set to 2048, the same function can be achieved also.
Signal
Symbol
Function
Applicable
mode
Clearing absolute position
PCLR
0x1F
P
Signal of clearing the multiturn absolute encoder.
If this digital input is valid, the multiturn data is clear while the single-turn data remains unchanged,
but the absolute position in the feedback is cleared.
Signal
Symbol
Function
Applicable
mode
Forward jogging
FJOG
0x23
P
If this digital input is valid, the motor executes forward jogging.
Signal
Symbol
Function
Applicable
mode
Reverse jogging
RJOG
0x24
P
If this digital input is valid, the motor executes reverse jogging.
Signal
Symbol
Function
Applicable
mode
Switching high/low jogging speed
JOGC
0x25
P
Signal of switching between the high jogging speed and low jogging speed. If this digital input is
valid, the drive jogs at high speed.
Signal
Symbol
Function
Applicable
mode
Enabling terminal jogging
DJOG
0x2C
P
If this digital input is valid, terminal jogging is valid.