The electrical installation should be done by qualified professionals, keeping in mind the 
following points: 

1.  Connect the equipment following the wiring diagram included in this manual. 

2.  Place a U-curve thermal-magnetic circuit breaker in the general power connection to 

protect the line in the case of a short in the circuit. 

3.  Place a differential circuit breaker in the general power connection to protect the 

equipment from possible grounding problems. The differential breaker should be 
minimum 30 mA. 

4.  Before installing the connections, be sure to disconnect the electricity so that the 

power supply is turned off. 

5.  Connect the power supply wires to the unit's input terminal. 

6.  Connect the grounding wire to its corresponding terminal. 

 

All local and national electricity codes concerning the protection of defects in electric power 
lines should be respected at all times during the electrical installation. 

Verify the torque of all electrical connections. 

The electrical resistance between the ground and any electric terminal will be verified to be over 
1 megaohm. Otherwise, the equipment will not start up until electrical loss is located and 
repaired. 

In the case of fluctuations in the power supply, a power supply stabilising system is 
recommended in order to protect the equipment. 

4.2.2 Electrical Scheme 

Hereafter are described the electrical schemes of all machine types. In all situatios, the 
compressor connexions are as seen on next figure: 

 

Figure 3: Compressor connexions. 

 

Summary of Contents for ASTRAL CDP-2

Page 1: ...ERIE ASTRAL CDP LINE ASTRAL CDP LINE DESHUMIDIFICADOR SERIES ASTRAL CDP LINE ASTRAL CDP LINE DEHUMIDIFIER S RIES ASTRAL CDP LINE ASTRAL CDP LINE DEHUMIDIFIER ASTRAL CDP LINE SERIES TECHNICAL MANUAL ST...

Page 2: ...ASTRALPOOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 2 of 69 FGHFGDH FGHFGH PUETA EN MARCH A Y FUNCIONAMIENTO...

Page 3: ...STRAL CDP LINE SERIE ASTRAL CDP LINE DEUMIDIFICATORE SERIE ASTRAL CDP LINE ASTRAL CDP LINE DESHUMIDIFICADOR SERIES ASTRAL CDP LINE ASTRAL CDP LINE DEHUMIDIFIER S RIES ASTRAL CDP LINE TECHNICAL MANUAL...

Page 4: ...DE LA CARCASA 26 9 CARGA DE GAS REFRIGERANTE 27 10 AVERIAS SUS CAUSAS Y SOLUCIONES 29 11 RECICLAJE DEL PRODUCTO 31 12 REPUESTOS 32 12 1 VISTA AMPLIADA CDP LINE 34 13 MODELOS 35 14 GARANT AS 35 FIGURAS...

Page 5: ...RUCTIONS 55 8 1 HOUSING REMOVAL 56 9 REFRIGERANT CHARGE 57 10 TROUBLESHOOTING GUIDE 59 11 PRODUCT RECYCLING 61 12 REPLACEMENT PARTS 62 12 1 CDP LINE EXPLODED VIEW 64 13 MODELS 65 14 GUARANTEES 66 FIGU...

Page 6: ...r el buen funcionamiento de la unidad deshumidificadora es necesario realizar un mantenimiento peri dico realizar un buen uso de ella y de no sobrepasar los l mites marcados por el fabricante 4 La ins...

Page 7: ...forma definitiva la climatizaci n de su piscina Le rogamos dedique unos minutos a la lectura de este manual para que pueda conocer el potencial de la m quina y tener en cuenta todas las circunstancia...

Page 8: ...dora se utiliza en instalaciones donde se requiere un control de humedad y temperatura individual de la zona aprovechando el calor latente de vaporizaci n y el propio rendimiento del equipo en calenta...

Page 9: ...rico con control total para garantizar un rendimiento ptimo con un m nimo consumo de energ a en todo momento La aplicaci n se basa en el control de una serie de elementos para mantener unas condicione...

Page 10: ...ia Nominal cv 1 1 1 4 1 3 4 2 Tipo Centr fugo Centr fugo Centr fugo Centr fugo Unidades 1 1 1 1 Caudal m3 h 700 800 1 000 1 200 Consumo Amp 1 1 1 1 1 1 1 1 Voltaje V 220 220 220 220 Gas Refrigerante R...

Page 11: ...liente las conexiones para el circuito hidr ulico presentan una distancia de 58 mm entre si y una altura respecto a a la base de la m quina de 610 mm 25mm 25mm Dos conexiones para el circuito hidr uli...

Page 12: ...os Consulte a su instalador Si se produce alguna anomal a olor a quemado etc pare la unidad retire la toma o corte la alimentaci n La reparaci n o instalaci n no deben ser realizadas por el cliente El...

Page 13: ...ponga nada Podr a producirse un accidente por la caida del objeto o de la unidad Verifique la compatibilidad de red con los datos indicados en el aparato antes de comenzar la instalaci n de la unidad...

Page 14: ...a tensi n ITC BT 31 Las conexiones el ctricas e hidr ulicas deben efectuarse seg n la normas en vigor NF C 15 100 CE 1 364 Las canalizaciones de las conexiones deben ser fijas Durante el funcionamient...

Page 15: ...ecesidades y condiciones de instalaci n Se instalan cables cuya secci n cumpla con las normativas actuales e impidan un calentamiento de estos y una ca da de tensi n A titulo orientativo se puede usar...

Page 16: ...onectar los cables de entrada de corriente a la borna de entrada de la m quina 6 Conectar el cable de toma tierra en la borna correspondiente para ello Se debe cumplir en todo momento lo que deja refl...

Page 17: ...ASTRALPOOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 17 of 69 ESPA OL Figura 3 Conexionado del compresor EQUIPO CON RESISTENCIAS ELECTRICAS...

Page 18: ...ASTRALPOOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 18 of 69 ESPA OL Figura 4 Esquema el ctrico equipos con resistencias el ctricas EQUIPO CON BATERIA DE AGUA CALIENTE...

Page 19: ...ASTRALPOOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 19 of 69 ESPA OL Figura 5 Esquema el ctrico equipos con bater a de agua caliente Bomba de recirculaci n no incluida...

Page 20: ...componentes internos del mismo Por esta raz n se ha incorporado un termostato de bulbo cuya misi n es tomar medidas de la temperatura del aire ambiente de modo que si esta temperatura disminuye por d...

Page 21: ...roduzcan fisuras o roturas en la instalaci n hidr ulica En la conexi n del equipo a la red hidr ulica no deberemos forzar los tubos de Cobre De esta forma evitaremos la rotura de los mismos Se ha de t...

Page 22: ...01 7005 es una combinaci n de higrostato y regulador de temperatura adecuado para ser empleado en peque as piscinas ba eras vestuarios salas de ba o Es necesario cuidar que el aparato no quede expuest...

Page 23: ...idad absorbida Dar tensi n al equipo conectando el interruptor general de fuerza externo a la unidad Una vez conectada la m quina verificar la intensidad absorbida por la fase Con el equipo en marcha...

Page 24: ...1 VENTILADOR SIEMPRE EN MARCHA recomendado En este modo de funcionamiento el ventilador permanecer en marcha siempre que la m quina est conectada aunque el recinto a climatizar se encuentre dentro de...

Page 25: ...iadamente a trav s de la misma Para efectuar su limpieza utilice agua con poca presi n y detergentes no abrasivos o espec ficos para ello COMPRESOR Se debe de comprobar el aceite del compresor en los...

Page 26: ...var siguiendo los siguientes pasos Partiendo de la posici n inicial de la unidad pasaremos a retirar los dos tornillos laterales 1 2 que sujetan la carcasa exterior Seguidamente procederemos a inclina...

Page 27: ...e introducirlo en el circuito de baja presi n a trav s de un cargador sistema de expansi n Despu s de haber puesto el circuito frigor fico bajo vac o despu s de haber instalado el cargador y haber con...

Page 28: ...ferentes instrumentos de b squeda de fugas aunque no todos son suficientemente sensibles para ciertos refrigerantes Es muy importante seleccionar un detector adecuado para el refrigerante que incorpor...

Page 29: ...o elimin ndola si ocurriera esto Comprobar el correcto funcionamiento de la v lvula Termost tica comprobando que el bulbo no ha perdido gas y que la toma de presi n no est obstruida sustituir en caso...

Page 30: ...de l quido revisando el recalentamiento ver apartado carga de gas INDICACIONES GENERALES Cualquier intervenci n en el circuito frigor fico debe realizarse siguiendo las normas de seguridad en vigor re...

Page 31: ...pueda contener PVC El plastificante m s usado en las aplicaciones de PVC es el DEHP dietil hexil ftalato Los ensayos realizados en diversos laboratorios demuestran que no presenta riesgo alguno para l...

Page 32: ...SISTENCIAS CDP 4 5 41501R0004 11 CHAPA SOPORTE CLIXON TODOS 41493R0011 12 MORDAZA TAPA TRASERA BATERIA EVAPORADORA TODOS 41493R0012 13 TAPA SUPERIOR CUADRO ELECTRICO CDP 2 3 41493R0013 13 TAPA SUPERIO...

Page 33: ...RIA EVAPORADORA CDP 2 3 41493R0039 38 TAPA TRASERA BATERIA EVAPORADORA CDP 4 5 41501R0020 39 CARCASA EXTERIOR CDP 2 3 41493R0040 39 CARCASA EXTERIOR CDP 4 5 41501R0021 40 CHAPA CUADRO ELECTRICO CDP 2...

Page 34: ...ASTRALPOOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 34 of 69 ESPA OL 12 1 VISTA AMPLIADA CDP LINE Figura 13 Vista ampliada de la unidad deshumidificadora...

Page 35: ...MPOTRADO 41503 ESTANDAR 41504 CDP LINE 4 BAT AGUA 12 KW EMPOTRADO 41505 ESTANDAR 41506 BAT ELECT 5 KW EMPOTRADO 41507 ESTANDAR 41508 CDP LINE 5 BAT AGUA 12 KW EMPOTRADO Tabla 5 Lista de modelos dispon...

Page 36: ...s productos a que hace referencia este manual 2 3 Para la eficacia de esta garant a el comprador deber seguir estrictamente las indicaciones del fabricante incluidas en la documentaci n que acompa a a...

Page 37: ...e of the unit and not to exceed the limits set by the manufacturer 4 The installation must be made by qualified technical personnel These personnel commit themselves to observe the instructions of the...

Page 38: ...ier unit into the equipment that can solve once and for all the air conditioning of your swimming pool Please read this manual carefully It will help you to learn the full potential of the equipment a...

Page 39: ...unit for swimming pools is used in facilities requiring individualised humidity control and temperature management taking advantage of the existing heat vapours and the equipment s heat output in ord...

Page 40: ...andard or built in Electric Panel Electrical control panel for complete process control and to guarantee optimum performance with minimum power consumption at all times The process control is based on...

Page 41: ...Nominal Power cv 1 1 1 4 1 3 4 2 Type Centrifugal Centrifugal Centrifugal Centrifugal Units 1 1 1 1 Flow m3 h 700 800 1 000 1 200 Consumption Amp 1 1 1 1 1 1 1 1 Voltage V 220 220 220 220 Refrigerant...

Page 42: ...istance between external connections for the hydraulic connections is 58 mm and a distance to the base of the equipment of 610 mm 25mm 25mm Two connections for the hydraulic circuit in case of machine...

Page 43: ...ce burning smell etc stop the unit retrieve the plug or turn the power off The repair or installation should never be performed by the client The unit must never be put under water or mud discharges a...

Page 44: ...ident Do not mount or place anything upon the unit The fall of the object or the unit could cause an accident Verify the network compatibility with the data specified in the unit before starting to in...

Page 45: ...ary Technical Instructions Low Voltage 31 ITC BT 31 The electrical and hydraulic connections must be made according to the applicable regulations NF C 15 100 EC 1 364 The ducting for the connections m...

Page 46: ...tion needs and conditions All wiring should comply with local and national electric codes and should not be prone to overheating and subsequent voltage failures As a guide you can use the general powe...

Page 47: ...power supply is turned off 5 Connect the power supply wires to the unit s input terminal 6 Connect the grounding wire to its corresponding terminal All local and national electricity codes concerning...

Page 48: ...ASTRALPOOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 48 of 69 ENGLISH ELECTRICAL BATTERY EQUIPPED Figure 4 Electrical Scheme for electrical battery equipped models...

Page 49: ...OOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 49 of 69 ENGLISH HEATING BATTERY EQUIPPED Figure 5 Electrical Scheme for heating battery equipped models Recirculation pump not...

Page 50: ...age to the internal components of the equipment For this reason a thermostat with probe has been included whose mission is to take ambient air temperature so if temperature drops below 21 C the thermo...

Page 51: ...der to avoid vibrations which may cause cracks or breakage in the hydraulic connections In order to avoid possible breakage do not force the copper tubes connected to the water supply Take into accoun...

Page 52: ...e of obstruction Obstacles should be maintained at a distance 5 CONTROLLER The HYG E 7001 7005 is a combination of a hygrostat and a room temperatura controller for use in swimming pools bathtubs dres...

Page 53: ...intensity absorbed Give power to the equipment by connecting the general power switch on the outside of the unit Once the unit is connected verify the intensity absorbed With the machine running verif...

Page 54: ...ting modes user selectable OPERATING MODE 1 FAN ALWAYS ON recommended In this operating mode the fan will always be on if the equipment main switch is ON even if the enclosure to be regulated is withi...

Page 55: ...them In order to clean it use water little pressure and non abrasive detergents or cleaning liquids made specifically for it COMPRESSOR Compressor oil must be checked in those unit models provided wi...

Page 56: ...ious maintenance procedures is to be carried following these steps Starting on the initial position of the unit proceed to remove the two side screws 1 2 that attach the housing Then proceed to tilt t...

Page 57: ...frigerant bottle must be introduced in the low pressure circuit by means of a charger expansion system After having discharged the cooling circuit and after having installed the charger and connected...

Page 58: ...re are various tools on the market used in order to detect leaks although not all of them are sufficiently sensitive to certain types of refrigerants It is very important to choose an adequate detecto...

Page 59: ...the obstruction if necessary Verify that the thermostatic valve is operating properly checking the bulb has no gas leaks and that the pressure inlet is free of obstruction Replace if needed High pres...

Page 60: ...that the noise does not come from any fluid leak from overheating see section of refrigerant charge GENERAL INSTRUCTIONS Any intervention in the refrigeration circuit must be made following the appli...

Page 61: ...lection from the rest of urban rubbish Possible effects over the environment or human health of the dangerous materials it may contain PVC The most used plastifying agent in the different PVC applicat...

Page 62: ...5 41501R0004 11 CLIXON PLATE ALL 41493R0011 12 REAR PLATE ROD ALL 41493R0012 13 UPPER ELECTRICAL PLATE CDP 2 3 41493R0013 13 UPPER ELECTRICAL PLATE CDP 4 5 41501R0005 14 AIR INLET OUTLET ROUND CDP 2 3...

Page 63: ...FRONT PLATE CDP 4 5 41501R0020 39 EXTERIOR ENCLOSURE CDP 2 3 41493R0040 39 EXTERIOR ENCLOSURE CDP 4 5 41501R0021 40 ELECTIRCAL PLATE CDP 2 3 41493R0041 40 ELECTIRCAL PLATE CDP 4 5 41501R0022 41 GROUND...

Page 64: ...ASTRALPOOL 2008 ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY DOCUMENT Page 64 of 69 ENGLISH 12 1 CDP LINE EXPLODED VIEW Figure 13 CDP LINE exploded view...

Page 65: ...LINE 2 HEAT BATTERY 6 KW BUILT IN 41497 STANDARD 41498 ELECT BATTERY 4 KW BUILT IN 41499 STANDARD 41500 CDP LINE 3 HEAT BATTERY 9 KW BUILT IN 41501 STANDARD 41502 ELECT BATTERY 5 KW BUILT IN 41503 ST...

Page 66: ...re in the installation procedure which is related to the lack of observance of the instructions contained in this manual will mean the cancellation of the warranty IMPORTANT The warranty will only hav...

Page 67: ...1 This warranty covers the products referred to in this manual 2 3 For the effectiveness of this warranty the buyer will have to strictly follow the manufacturer instructions included in the documenta...

Page 68: ...atibility directive 2004 108 EC and its modifications Low voltage equipment directive 2006 95 EC Directive 2000 14 CE concerning noise produced by equipment for outdoors use as amended by Directive 20...

Page 69: ...CONTENU DE CE DOCUMENT SANS AVIS DE WIR BEHALTEN UNS DAS RECHT VOR DIE CHARAKTERISTIKA UNSERER PRODUKTE ODER DEN INHALT DIESES DOKUMENTS OHNE VORHERIGE ANK NDIGUNG VOLLST NDIG ODER TEILWEISE ZU NDERN...

Reviews: