CAUTION
Dose pool with a small amount of chlorine before starting the eQ. If no chlorine is sensed the eQ may go to fail safe mode
and not start up. Some Chlorine should be present before starting the unit..
Before installing probes, balance pool water. Total Alkalinity (TA) must be 80 to 120 ppm, Calcium Hardness should be 180
to 250 ppm, and pH must be between 7.2 and 7.6.
Cyanuric Acid, sometimes referred to as stabiliser or sunscreen will suppress the Chlorine (ORP) reading when the Chlorine
sensor is connected. Refer to section on setting chlorine levels if Cyanuric Acid is present in your pool.
Product is designed to run with ACID diluted to water to acid ratio of 2:1 should always be followed as the machines
dosing rate is formulated around the diluted solution. Using neat acid can lead to overdosing the pH level.
SAVE THESE INSTRUCTIONS
WARNING
People with infectious diseases should not use a spa or hot tub.
Children should not use spas or hot tubs without adult supervision.
To avoid injury, exercise care when entering or exiting the spa or hot tub.
Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
Before entering a spa or hot tub, measure the water temperature with an accurate thermometer.
Do not use a spa or hot tub immediately following strenuous exercise.
Prolonged immersion in a spa or hot tub may be injurious to your health.
Do not permit any electric appliance (such as a light, telephone, radio, or television) within 3.5 metres of a spa or hot tub.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
Water temperature in excess of 38°C may be hazardous to your health.
Attention Installer:
Install to provide drainage of compartment for electrical
components.
WARNING
A terminal bar marked "GROUND" is provided within the controller. To reduce the risk of electrical shock which can cause
serious injury or death, connect this terminal bar to the grounding terminal of your electric service or supply panel with a
continuous copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying
this equipment in accordance with
the latest, enforced version of AS/NZS 3000
. In addition, where required, bonding
should be extended in accordance with
the latest, enforced version of AS/NZS 3000
to any metal ladders, water pipes,
or other metal within 3.5 m of the pool/spa.