WARNING:
High Pressure. System contents under
pressure. Can cause serious injury and burns or
equipment and property damage. Relieve pressure
before servicing.
CAUTION
: For maximum performance and motor
life, do not allow pump motor to stall. A prolonged
stall condition will cause motor to go into thermal
overload.
5.3.2 Flow Adjustments
Flow Control Valve
An adjustable pressure regulating device is mounted on the pump
under the melt unit chassis. See illustration below.
1. Adjust flow control from the lower right side of melt unit
using the hex wrench supplied with unit.
2. To increase pressure, turn hex wrench clockwise.
3. To decrease pressure, turn hex wrench counterclockwise.
4. To achieve minimum pressure and lowest flow rate, turn hex
wrench fully counterclockwise.
5. Gradually turn hex wrench clockwise until desired pressure
and flow rate is reached.
!
Increase
Hex
wrench
Decrease
0960141a
18
LS10 and LS20 19600-121
Copyright 2010 Astro Packaging