12
5.3.1
Connection of the AC wiring
•
Open the breaker or fuse between P V Inverter and utility.
•
For the inverter , connecting AC wires as follows:
•
the strip insulation length of L, N ,PE is 5mm.
•
all wires through the shell and screw to the AC terminal connect
•
screwing the shell to inverter and pressing screw cap tighten.
Wire requirements
Product Model
_ (mm)
Area(mm²)
AWG no.
CHPI 3.6KTL-M2
_2.59
5.260
10
CHPI 4.2KTL-M2
_2.59
5.260
10
CCHPI 5KTL-M2
_2.59
5.260
10
5.4
Connecting to PV Panels(DC input)
Warning:
•
Risk of electric shock and fire, use only with PV modules with a maximum system voltage of 600Vdc!
•
For instance, if the positive pole of a string is connected at input zone A and the string’s negative pole at input zone B, this is
called a mixed connection. Only connect strings at one input zone and never mix the input zones A and B!