29
No Utility
1.
Grid is not connected.
2.
Check grid connection cables.
3.
Check grid usability.
12. INVERTER FAILURE
PV Over Voltage
1.
Check the open PV voltage, if it is greater than or too close to 600VDC.
2.
If PV voltage is less than 600VDC, and the problem still occurs, please call local service.
Consistent Fault
1.
Disconnect PV (+) or PV (-) from the input, restart the PV-Inverter.
2.
If it does not work, call service.
> If there is no display on the panel, please check PV-input connections. If the voltage is higher than 150V, call your local
service.
> During periods of little or no sunlight, the PV-Inverter may continuously start up and shut down. This is due to insufficient
power generated to operate the control circuits.
13. SPECIFICATIONS
Max. DC power
Max. DC voltage
Start voltage
DC nominal voltage
PV voltage range
MPP voltage range
Number of MPP trackers/
strings per MPP tracker
Max. input current /
per string
3800W
600V
150V
360V
100V-600V
175V-550V
2/2
2X10A/10A
4400W
600V
150V
360V
100V-600V
175V-550V
2/2
2X15A/15A
5000W/5200W
600V
150V
360V
100V-600V
175V-550V
2/2
2X15A/15A
CHPI 3.6KTL-M2 CHPI 4.2KTL-M2 CHPI 5KTL-M2
Input Data