12
⑧
For the installation method shown in Fig. 9, the
module needs to be fixed with professional clamps
(as shown in Fig. 13), and the overlap between the
C side of the module and the rail should be ≥
15mm. Chint’s limited warranty will be void if
improper clamps or improper installation is used.
Figure 13 Mounting requirements for rails overlapping the
short-side frame
Table 1 Installation range and corresponding values
Module type
Module
dimension
L*W*H (mm)
Installation method
Fig 2 & Fig 3
& Fig 4
Fig 5
Fig 8
Fig 9
Fig 6
CHSM6610M
CHSM6610M/HV
CHSM6610P
CHSM6610P/HV
CHSM6610M(BL)
1648*990*35
1648*990*40
+5400Pa
-2400Pa
---
+5400/-2400Pa
Installation scope
198~408mm
+2400/-2400Pa
Installation scope
50~200mm
---
1650*992*35
1650*992*40
+5400Pa
-2400Pa
---
+5400/-2400Pa
Installation scope
198~408mm
+2400/-2400Pa
Installation scope
50~200mm
---
CHSM60M-HC
CHSM60P-HC
CHSM60M(BL)-HC
CHSM60M/LV-HC
CHSM60M(BLH)-HC
1666*992*35
+5400Pa
-2400Pa
---
+5400/-2400Pa
Installation scope
207~408mm
+2400/-2400Pa
Installation scope
50~200mm
---
CHSM60M-HC
CHSM60P-HC
CHSM60M(BL)-HC
1675*992*35
+5400Pa
-2400Pa
---
+5400/-2400Pa
Installation scope
215~415mm
+2400/-2400Pa
Installation scope
50~200mm
---