15
CHSM72M(BL)-HC
CHSM72M(BLH)-HC
2000*992*40
2000*992*35
+5400Pa
-2400Pa
+5400Pa
-2400Pa
+5400/-2400Pa
Installation scope
315~505mm
---
+2400Pa
-2400Pa
+Bumper
CHSM72M-HC
CHSM72P-HC
CHSM72M/LV-HC
CHSM72M(BL)-HC
CHSM72M(BLH)-HC
CHSM72N-HC
CHSM72N(BLH)-HC
CHSM72N(BL)-HC
2018*1002*40
2018*1002*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
350±50mm
---
+2400Pa
-2400Pa
+Bumper
2108*1048*35
2094*1038*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
400±50mm
---
+2400Pa
-2400Pa
+Bumper
2256*1133*35
2279*1134*35
2278*1134*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
400~450mm
---
+1800Pa
-1800Pa
+Bumper
CHSM66M-HC
CHSM66M(BL)-HC
CHSM66N-HC
2384*1303*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
475~525mm
---
+1800Pa
-1800Pa
+Bumper
CHSM55M-HC
CHSM55M/LV-HC
2384*1096*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
474~525mm
---
+1800Pa
-1800Pa
+Bumper
CHSM50M-HC
CHSM50M/LV-HC
2172*1096* 35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
375~425mm
---
+1800Pa
-1800Pa
+Bumper
CHSM78N-HC
CHSM78N/LV-HC
CHSM78M-HC
CHSM78M/LV-HC
2465*1134*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
400~450mm
---
+1800Pa
-1800Pa
+Bumper
6
Electrical Installation
6.1
Electrical characteristics
The electrical characteristics are detailed in the PV
module product manual.
The rated values of electrical characteristics, including
I
sc
, V
oc
and P
mpp
, have some tolerance with the
measured values at standard condition: ±5% for I
sc
,
±3% for V
oc
and ±3% for P
mpp
. The standard test
condition refers to 1000W/m
2
, AM1.5 and cell
temperature at 25℃.
According to IEC and UL standards, the standard
maximum system voltage for the regular module series
is 1000V, the 1500V standard products are also
available according to the requirements. The IEC &
UL standard maximum system voltage for half-cell
module series is 1500V (except for BL &LV series PV
modules).
The actual maximum voltage must be less than the
standard maximum system voltage and the maximum
output voltage of the inverter and other electrical
equipment installed in the system. The number of PV
modules connected in series should match the voltage