to  another  with  opposite  polarity,  irreversible 

damage  can  be  caused  to  the  PV  module  product. 

Be sure to confirm the voltage and polarity of each 

string  before  making  a  parallel  connection.  If 

measurements reveal opposite polarity or a voltage 

difference  greater  than  10V  between  the  strings, 

check 

their 

structural 

configuration 

before 

proceeding with the connection.   

 

The  number  of  modules  connected  in  series  and 

parallel should be reasonably designed according to 

the system configuration. 

 

PV  modules  with  different  electrical  performance 

models cannot be connected in one string. 

 

The system shall use special cables and connectors 

for  PV  system  and  ensure  that  all  connections  are 

securely fastened. The cable must be 4mm

2

 (i.e. 12 

AWG)  and  withstand  the  maximum  possible 

open-circuit voltage of the PV system. 

 

When fixing the cable to the rack, it is necessary to 

avoid mechanical damage to the cable or to the PV 

module. Do not press the cable hard. To secure the 

cable  to  the  rack  in  the  proper  way,  specially 

designed UV-resistant coils and cable clips must be 

used. Avoid direct sunlight and water soaking to the 

cable. 

 

Keep  the  connectors  dry  and  clean  and  make  sure 

that the nuts on the connectors are tightened before 

connecting  them.  Do  not  connect  the  connectors 

when they  are damp, contaminated or  in other  bad 

conditions.  Avoid  exposing  connectors  to  direct 

sunlight and soaking in water. Avoid the connectors 

falling  on  the  ground  or  the  roof.  Do  not  plug  or 

unplug  the  connectors  when  the  PV  module  is  in 

live  state.  When  it  is  necessary  to  remove  the 

connectors,  ensure  that  the  PV  module  is  not  in 

working  condition  and  that  professional  unlocking 

tools and safety measures are used. Direct dragging 

and pulling is forbidden. 

 

The junction box of the PV module contains bypass 

diodes connected in parallel to the string of the PV 

module.  The  bypass  diode  in  the  junction  box 

prevents  module  degradation  due  to  shading  or 

covering.  Refer  to  the  junction  box  diode 

specification  provided  in  the  relevant  product 

datasheet for more details. I When the localized hot 

spot  phenomenon  occurs  in  the  PV  module  due  to 

partial  shading  or  coverage,  the  diode  in  the 

junction box will start  to work, so that the module 

current will no longer flow through the hot spot cell, 

so  as  to  limit  the  heat  and  loss  of  the  PV  module. 

When a diode failure is suspected or found, please 

contact Chint Solar and do not attempt to open the 

junction box cover. 

6.3

 

Grounding 

The  PV  modules  are  designed  with  an  anodised, 

corrosion-resistant  aluminum  alloy  frame  as  a  rigid 

support. To ensure safety and to avoid lightning strikes 

and  electrostatic  damage  to  the  PV  modules,  the  PV 

module  frame  must  be  earthed.  The  earthing  device 

must  be  in  full  contact  with  the  interior  of  the 

aluminum  alloy  of  the  frame,  penetrating  the  surface 

oxide  film.The  following  is  the  specific  grounding 

method, as shown in Fig. 15. 

Summary of Contents for CHSM54M(BL)-HC

Page 1: ...1 Crystalline Silicon PV Module Installation Manual...

Page 2: ...1 Transport 6 4 2 Unpack 7 4 3 Stack 7 5 Mechanical installation 7 5 1 Environment 7 5 2 Tilt angle selection 8 5 3 Mounting Guide 8 5 3 1 Bolted mounting 9 5 3 2 Clamped mounting 10 6 Electrical Inst...

Page 3: ...ed with is beyond the control of Chint Solar Chint shall not be liable for any form of loss including but not limited to loss damage casualty or additional cost caused by improper installation operati...

Page 4: ...a or PV module storage area It is forbidden to install or use damaged PV modules It is forbidden to repair PV modules by unauthorized personnel including but not limited to replacing any part of PV mo...

Page 5: ...and be aware of bumps in the corners When installing or repairing the PV system do not wear any metal accessories to avoid the risk of electric shock if it is installed far above the ground please we...

Page 6: ...connector or make electrical connections in any other way 4 Handling and unpacking If the PV module is not in use please do not open the product packaging The goods should be stored in a dark dry and...

Page 7: ...from colliding and scratching with the cement surface hard object on the ground color steel tile metal corrugated etc When the PV modules are stacked they must be neatly and stably stacked on a horiz...

Page 8: ...tion The tilt angle of a PV module refers to the angle between the surface of the PV module and the ground surface as shown in Fig 1 The power output of a PV module is maximized when it faces the sun...

Page 9: ...raction effect therefore the space between two adjacent PV module frames should be no less than 10mm when mounted For detailed installation methods please refer to the following specifications 5 3 1 B...

Page 10: ...e installed across the support frame Fig 8 or parallel to the frame of the photovoltaic module Fig 9 When using clamps to install each module must be secured with a minimum of 4 clamps Fig 8 Rails ove...

Page 11: ...shown in Fig 10 and the fringe clamp shown in Fig 11 and Fig 12 The mid clamp has dimensions of a 40 mm b 26 mm c 5 mm d 28 mm 9 mm For module of 182mm wafer the size of mid and fringe clamp must mee...

Page 12: ...00Pa 2400Pa 5400 2400Pa Installation scope 198 408mm 2400 2400Pa Installation scope 50 200mm CHSM60M HC CHSM60P HC CHSM60M BL HC CHSM60M LV HC 1666 992 35 5400Pa 2400Pa 5400 2400Pa Installation scope...

Page 13: ...M HC CHSM54M BL HC CHSM54M LV HC 1708 1133 30 1708 1133 35 1722 1134 30 1722 1134 35 5400Pa 2400Pa 5400 2400Pa Installation scope 359 50mm 1400 1400Pa Installation scope 200 50mm CHSM6612M CHSM6612M H...

Page 14: ...m voltage for the regular module series is 1000V the 1500V standard products are also available according to the requirements The IEC UL standard maximum system voltage for half cell module series is...

Page 15: ...ge ratings conductor capacities fuse ratings and control sizes for PV output Depending on the maximum rated fuse current of the PV module and the local electrical installation standards the connection...

Page 16: ...ng connectors to direct sunlight and soaking in water Avoid the connectors falling on the ground or the roof Do not plug or unplug the connectors when the PV module is in live state When it is necessa...

Page 17: ...that meet the requirements of UL 467 and is suitable for electrical bonding and grounding of PV modules Other grounding methods may be used when the racking system is tested following the UL 2703 req...

Page 18: ...it is generally not necessary to clean the PV module as the rainfall will provide a self cleaning effect If there is a large accumulation of dirt on the PV module surface that has seriously affected t...

Page 19: ...released in June 2018 Rev 1 1 released in July 2020 Rev 1 2 released in October 2021 CHINT SOLAR ZHEJIANG Co Ltd Add 1335 Bin an Rd Binjiang District Hangzhou China 310053 Tel 86 571 5603 1888 Fax 86...

Reviews: