4   

     

 

 

WARNING 

Read  and  understand  all  safety  instructions  before 

installing,  wiring,  handling,  and/or  maintaining  PV 

modules.  PV  modules  generate  direct  current 

electricity  when  they  are  exposed  to  sunlight  or  other 

light sources. Whether the module is connected or not, 

direct contact with the live part of the module such as 

the wiring terminal may cause personal injury or even 

death. 

3.1

 

General safety 

 

Before installation, please contact the relevant local 

authority  to  make  sure  the  installation  permit  and 

installation  inspection  requirements  can  meet  the 

local requirements. The  installation  process should 

comply  with  the  safety  rules  applicable  to  all 

components  in  the  system,  including  cables, 

terminals,  charging  monitors,  batteries,  inverters, 

etc. 

 

Installation and maintenance must be completed by 

professionally  qualified  engineers.  During  the 

installation, wear safety helmets, insulating gloves, 

safety  shoes  and  use  insulating  tools  to  avoid  the 

direct  contact  with  a  DC  voltage  of  30V  or  even 

higher. 

 

When installing or operating PV modules on rainy 

days or dewy mornings, take appropriate protective 

measures  to  prevent  moisture  from  penetrating  the 

connectors.  Unauthorized  personnel  are  prohibited 

from  approaching  the  installation  area  or  PV 

module storage area. 

 

It  is  forbidden  to  install  or  use  damaged  PV 

modules. 

 

It  is  forbidden  to  repair  PV  modules  by 

unauthorized  personnel,  including  but  not  limited 

to  replacing  any  part  of  PV  modules  (such  as 

diodes, junction boxes, connectors, etc.). 

 

It  is  forbidden  to  plug  in  connectors  of  different 

types and models. 

 

It  is  forbidden  to  expose  PV  modules  to  the 

following  substances:  grease  or  organic  ester 

compounds  (e.g.  DOP,  plasticizers),  aromatics, 

phenols,  ketones,  halogenated  substances,  mineral 

oil,  alkanes  (e.g.  gasoline,  cleaning  lubricants, 

electronic  resurrection  agents),  alcohol,  ,  adhesive 

sheets that can generate oxime gas and potting glue 

(only 

for 

connectors, 

such 

as 

KE200, 

CX-200/chemlok, etc.), TBP (plasticizer), detergent, 

etc.,  to  avoid  chemical  damage  and  affect  the 

electrical safety performance of PV modules. 

 

Photovoltaic  module  installation  is  prohibited  on 

windy days. 

 

Avoid focusing sunlight on PV modules. 

 

It is forbidden to place PV modules near equipment 

or where flammable gas may be generated. 

 

It  is  forbidden  to  install  PV  modules  on  movable 

platform, excepting tracking systems. 

 

It is forbidden to disassemble and move any part of 

the PV module; if the connector of the PV module 

is wet, do not perform any actions to avoid the risk 

of electric shock. 

 

It  is  forbidden  to  connect  or  disconnect  the  PV 

module when there is electrical  current or external 

electrical current. 

 

The  cover  of  the  junction  box  should  always  be 

kept closed. 

Summary of Contents for CHSM54M(BL)-HC

Page 1: ...1 Crystalline Silicon PV Module Installation Manual...

Page 2: ...1 Transport 6 4 2 Unpack 7 4 3 Stack 7 5 Mechanical installation 7 5 1 Environment 7 5 2 Tilt angle selection 8 5 3 Mounting Guide 8 5 3 1 Bolted mounting 9 5 3 2 Clamped mounting 10 6 Electrical Inst...

Page 3: ...ed with is beyond the control of Chint Solar Chint shall not be liable for any form of loss including but not limited to loss damage casualty or additional cost caused by improper installation operati...

Page 4: ...a or PV module storage area It is forbidden to install or use damaged PV modules It is forbidden to repair PV modules by unauthorized personnel including but not limited to replacing any part of PV mo...

Page 5: ...and be aware of bumps in the corners When installing or repairing the PV system do not wear any metal accessories to avoid the risk of electric shock if it is installed far above the ground please we...

Page 6: ...connector or make electrical connections in any other way 4 Handling and unpacking If the PV module is not in use please do not open the product packaging The goods should be stored in a dark dry and...

Page 7: ...from colliding and scratching with the cement surface hard object on the ground color steel tile metal corrugated etc When the PV modules are stacked they must be neatly and stably stacked on a horiz...

Page 8: ...tion The tilt angle of a PV module refers to the angle between the surface of the PV module and the ground surface as shown in Fig 1 The power output of a PV module is maximized when it faces the sun...

Page 9: ...raction effect therefore the space between two adjacent PV module frames should be no less than 10mm when mounted For detailed installation methods please refer to the following specifications 5 3 1 B...

Page 10: ...e installed across the support frame Fig 8 or parallel to the frame of the photovoltaic module Fig 9 When using clamps to install each module must be secured with a minimum of 4 clamps Fig 8 Rails ove...

Page 11: ...shown in Fig 10 and the fringe clamp shown in Fig 11 and Fig 12 The mid clamp has dimensions of a 40 mm b 26 mm c 5 mm d 28 mm 9 mm For module of 182mm wafer the size of mid and fringe clamp must mee...

Page 12: ...00Pa 2400Pa 5400 2400Pa Installation scope 198 408mm 2400 2400Pa Installation scope 50 200mm CHSM60M HC CHSM60P HC CHSM60M BL HC CHSM60M LV HC 1666 992 35 5400Pa 2400Pa 5400 2400Pa Installation scope...

Page 13: ...M HC CHSM54M BL HC CHSM54M LV HC 1708 1133 30 1708 1133 35 1722 1134 30 1722 1134 35 5400Pa 2400Pa 5400 2400Pa Installation scope 359 50mm 1400 1400Pa Installation scope 200 50mm CHSM6612M CHSM6612M H...

Page 14: ...m voltage for the regular module series is 1000V the 1500V standard products are also available according to the requirements The IEC UL standard maximum system voltage for half cell module series is...

Page 15: ...ge ratings conductor capacities fuse ratings and control sizes for PV output Depending on the maximum rated fuse current of the PV module and the local electrical installation standards the connection...

Page 16: ...ng connectors to direct sunlight and soaking in water Avoid the connectors falling on the ground or the roof Do not plug or unplug the connectors when the PV module is in live state When it is necessa...

Page 17: ...that meet the requirements of UL 467 and is suitable for electrical bonding and grounding of PV modules Other grounding methods may be used when the racking system is tested following the UL 2703 req...

Page 18: ...it is generally not necessary to clean the PV module as the rainfall will provide a self cleaning effect If there is a large accumulation of dirt on the PV module surface that has seriously affected t...

Page 19: ...released in June 2018 Rev 1 1 released in July 2020 Rev 1 2 released in October 2021 CHINT SOLAR ZHEJIANG Co Ltd Add 1335 Bin an Rd Binjiang District Hangzhou China 310053 Tel 86 571 5603 1888 Fax 86...